White Battery Operated Smoke Alarm 85dB 10 Year Lithium Battery Smoke Detector With Photoelectric Sensor
| Place of Origin | China |
|---|---|
| Brand Name | Symank |
| Certification | CE/ROHS/UKCA/SGS |
| Model Number | JKD-518 |
| Certificates | Smoke alarm EN14604(CPR) Ce...ti.pdf |
| Minimum Order Quantity | 100pcs |
| Price | Negotiable |
| Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Delivery Time | 5 days |
| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 50K/Month |
| Name | Battery Operated Smoke Alarm | Item | Conventional Smoke Detector |
|---|---|---|---|
| Test Button | Yes | Sensor Type | Photoelectric Sensor |
| Color | White | Reset Time | Less Than 1 Second |
| Dimensions | Approx. 120mm Diameter X 40mm Height | Operating Temperature Range | -10°C To 50°C (14°F To 122°F) |
| Certifications | SGS Listed, CE Compliant | Battery Life | Up To 10 Years |
| Power Source | Battery Operated | Environmental Temperature | -10℃ ~ +50℃ |
| Humidity Range | Up To 85% RH | ||
| Highlight | White Battery Operated Smoke Alarm,Battery Operated Smoke Alarm 85dB,10 Year Lithium Battery Smoke Detector |
||
Long Life Smoke Detector with a Sealed 10-Year Lithium Battery
Product Overview
The JKD-518 is a long life photoelectric smoke detector developed for residential fire protection. It combines a photoelectric smoke sensor with a sealed lithium battery designed to support the detector throughout its intended 10-year service life, helping reduce routine maintenance compared with replaceable-battery models.
The detector is designed for standalone operation and does not require mains power, Wi-Fi or Zigbee connectivity. Once installed, it continuously monitors for smoke and provides an audible alarm of at least 85dB when smoke reaches the specified alarm threshold.
Manufactured according to EN14604:2005/AC:2008, the JKD-518 is also available in versions meeting AS3786:2023 requirements for customers serving the Australian market. This allows distributors and brand owners to source products for different regions from a single manufacturing partner.
Why Choose a Long Life Smoke Detector?
For residential projects, reducing maintenance is often as important as meeting technical standards.
A long-life smoke detector helps:
- Reduce scheduled battery replacement
- Lower maintenance costs over the product's service life
- Minimize the risk of the detector being left without power due to battery removal
- Improve convenience for homeowners and property managers
- Support large residential developments where maintenance efficiency is a priority
The sealed battery design also helps ensure that the detector remains powered throughout its intended service life under normal operating conditions.
Product Features
Sealed 10-Year Lithium Battery
The integrated lithium battery is designed to operate for the intended life of the detector without routine battery replacement, reducing ongoing maintenance requirements.
Photoelectric Smoke Sensor
The detector uses a photoelectric reflection sensor that responds to visible smoke particles generated during many slow-developing residential fires.
Audible Alarm
When smoke reaches the alarm threshold, the detector emits an audible warning of ≥85dB, helping alert occupants to a potential fire hazard.
Test and Silence Function
A built-in test button allows users to verify normal operation, while the silence function temporarily mutes nuisance alarms for approximately 10 minutes after safety has been confirmed.
Simple Installation
The detector is suitable for ceiling or wall installation in residential buildings. The compact housing is designed to blend into modern home interiors while remaining accessible for routine testing.
Typical Applications
The JKD-518 is suitable for:
- Houses
- Apartments
- Residential developments
- Rental properties
- Hotels
- Holiday homes
- Student accommodation
- Property management companies
- Home improvement retailers
- Fire safety distributors
Its long-life battery design makes it especially suitable for projects where reducing routine maintenance is an important purchasing consideration.
Certification & Documentation
The JKD-518 is manufactured according to EN14604:2005/AC:2008 and can be supplied with documentation supporting residential fire safety projects.
Available documents include:
- EN14604 documentation
- AS3786:2023 documentation (where applicable)
- SGS reports
- UKCA documentation
- RoHS declaration
- Product specification sheet
- User manual
- Product label artwork
Documentation should always be verified against the exact product model and destination market before mass production.
Smoke alarm EN14604(CPR) Certi.pdf
Certificate SMK41606 20250822.pdf
Technical Specifications
| Item | Specification |
|---|---|
| Model | JKD-518 |
| Product Type | Long Life Smoke Detector |
| Sensor | Photoelectric Reflection |
| Battery | Sealed 10-Year Lithium Battery |
| Product Standard | EN14604:2005/AC:2008 |
| Australian Standard | AS3786:2023 (available configuration) |
| Alarm Volume | ≥85dB |
| Silence Function | Approx. 10 Minutes |
| Installation | Ceiling / Wall |
| Product Life | 10 Years |
| Application | Residential Indoor Use |
Frequently Asked Questions
What makes this a long life smoke detector?
The JKD-518 combines a sealed lithium battery with a detector designed for a 10-year service life, eliminating the need for routine battery replacement during normal use.
Is the battery replaceable?
No. The lithium battery is permanently sealed inside the detector and is intended to last for the detector's service life.
Can this model be sold in Australia?
Yes. Versions complying with AS3786:2023 are available for Australian residential projects.
Is OEM customization available?
Yes. We provide private-label manufacturing, customized packaging, product labels and multilingual user manuals.
Can samples be requested?
Yes. Samples are available for product evaluation before confirming bulk production.
Request Product Information
If you are sourcing long life smoke detectors for residential distribution, OEM branding or private-label projects, contact us with your target market, estimated order quantity and branding requirements. We will provide the appropriate technical documentation, customization options and a quotation tailored to your project.