Battery Operated Fire Alarm Smoke Detector 3V 10 Year Smoke Detectors EN14604 Certified
| Place of Origin | China |
|---|---|
| Brand Name | Symank |
| Certification | CE/ROHS/SGS/UKCA |
| Model Number | JKD-516 |
| Certificates | Smoke alarm EN14604(CPR) Ce...ti.pdf |
| Minimum Order Quantity | 100pcs |
| Price | Negotiable |
| Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Delivery Time | 5 days |
| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 50K/Month |
| Item | Fire Alarm Smoke Detector | Humidityrange | 10% To 85% Non-condensing |
|---|---|---|---|
| Operatingtemperaturerange | -10°C To 50°C | Certifications | SGS Listed, CE Compliant |
| Color | White | Operatingvoltage | 3V DC |
| Powersource | Battery Operated | Sensortype | Photoelectric Sensor |
| Productname | Fire Alarm Smoke Detector | Reset Time | Less Than 1 Second |
| Usage | Smoke Detection In Fire Alarm System | Batterylife | Up To 3 Years |
| Installationtype | Ceiling Or Wall Mount | ||
| Highlight | Battery Operated Fire Alarm Smoke Detector,Fire Alarm Smoke Detector 3V,10 Year Smoke Detectors EN14604 Certified |
||
Battery Operated Residential Smoke Alarm for European Distribution
Product Overview
The JKD-516 is a battery operated smoke alarm designed for residential fire detection. Powered by two replaceable AA batteries, it operates independently without external wiring, wireless communication or a mobile application, making it suitable for apartments, houses, hotels and residential renovation projects.
Using a photoelectric smoke sensor, the detector responds to visible smoke particles generated during the early stages of many household fires. When smoke reaches the specified alarm threshold of 0.25dB/m, the detector activates an audible alarm of at least 85dB at three metres.
Designed in accordance with EN 14604:2005/AC:2008, the JKD-516 is available for OEM manufacturing, distributor supply and private-label programmes. Customized branding, multilingual manuals and retail packaging can be prepared according to project requirements.
Why Choose a Battery Operated Smoke Alarm?
Battery operated smoke alarms remain one of the most practical solutions for residential fire protection because they can be installed without modifying the building's electrical system. This makes them suitable for both new installations and replacement projects.
The JKD-516 uses two standard AA batteries, allowing users to replace the batteries during the detector's service life instead of replacing the complete unit. For distributors, this configuration also simplifies after-sales support because replacement batteries are widely available in most markets.
With a standby current of less than 50μA, the detector is designed for low power consumption under normal operating conditions.
Key Features
Photoelectric Detection Technology
The optical smoke sensor is designed to detect smoke particles commonly produced by smouldering household fires. Compared with other sensing technologies, photoelectric detection is widely adopted for residential smoke alarm applications.
Replaceable AA Battery Design
Powered by two 1.5V AA batteries, the detector does not require mains wiring or additional power accessories. Battery replacement can be completed without changing the entire alarm.
EN14604 Compliance
The product is manufactured according to EN14604:2005/AC:2008, the European product standard for residential smoke alarms.
Audible Warning
The alarm sound reaches ≥85dB at a distance of three metres, providing a clear audible warning when smoke is detected.
Temporary Alarm Silence
The silence function temporarily suppresses the alarm for approximately ten minutes after the user confirms that there is no fire emergency, helping reduce interruptions caused by cooking fumes or similar non-emergency conditions.
Typical Applications
The JKD-516 is suitable for a wide range of residential indoor environments, including:
- Houses
- Apartments
- Bedrooms
- Living rooms
- Hallways
- Holiday homes
- Student accommodation
- Residential property developments
- Hotels and guest rooms
The detector is designed for ceiling or wall installation, with a recommended maximum coverage area of 40m² per room, depending on room layout and local installation requirements.
OEM & Private Label Services
This model is available for OEM and private-label cooperation.
Customization options include:
- Product logo printing
- Private label packaging
- Customized instruction manuals
- Barcode labels
- Retail gift box design
- Outer carton printing
- Multilingual documentation
Before production begins, all customized artwork is reviewed to ensure that certification markings and product information remain consistent with the approved documentation.
Certification & Documentation
The JKD-516 is supported by documentation for international distribution projects.
Available documentation may include:
- EN14604 certification documents
- SGS reports
- UKCA documentation
- RoHS declaration
- Product specification sheet
- User manual
- Product label artwork
Importers are encouraged to verify that all documents correspond to the exact model number and destination market before placing volume orders.
Smoke alarm EN14604(CPR) Certi.pdf
Technical Specifications
| Specification | Details |
|---|---|
| Model | JKD-516 |
| Sensor | Photoelectric |
| Standard | EN14604:2005/AC:2008 |
| Power Supply | 2 × AA Batteries |
| Smoke Sensitivity | 0.25dB/m |
| Alarm Volume | ≥85dB (3m) |
| Silence Function | Approx. 10 Minutes |
| Product Life | 10 Years After Manufacture |
| Standby Current | <50μA |
| Alarm Current | <70μA |
| Operating Temperature | -10°C to +50°C |
| Humidity | <95% RH (Non-condensing) |
| Installation | Ceiling / Wall |
| Coverage | Up to 40m² |
| Dimensions | Φ120 × 39mm |
| Weight | 180 ±10g |
Frequently Asked Questions
Does this detector require Wi-Fi?
No. The JKD-516 is a standalone smoke alarm and operates independently.
Can the batteries be replaced?
Yes. It uses two standard AA batteries that can be replaced during the product's service life.
Is it suitable for private-label projects?
Yes. Branding, packaging and user manuals can all be customized for OEM customers.
Which markets is this model intended for?
It is designed for residential applications requiring compliance with EN14604. Importers should also confirm any additional local regulatory requirements before sale.
Can samples be provided before bulk production?
Yes. Samples are available so buyers can evaluate the product before confirming volume orders.
Request a Quotation
If you are sourcing battery operated smoke alarms for distribution, retail or private-label projects, contact us with your target market, estimated quantity and branding requirements. We will prepare a quotation together with the relevant technical documentation and OEM customization options.
