High Reliability Fire Alarm Smoke Detector Commercial Fire Safety Smoke Detector 3V
| Place of Origin | China |
|---|---|
| Brand Name | Symank |
| Certification | CE/ROHS/SGS/UKCA |
| Model Number | JKD-516 |
| Certificates | Smoke alarm EN14604(CPR) Ce...ti.pdf |
| Minimum Order Quantity | 100pcs |
| Price | Negotiable |
| Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Delivery Time | 5 days |
| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 50K/Month |
| Name | Fire Alarm Smoke Detector | Material | ABS Fireproof |
|---|---|---|---|
| Environmental Temperature | -10℃ ~ +55℃ | Battery Life | Up To 3 Years |
| Detection Type | Photoelectric | Alarm Sound Level | 85 DB At 10 Feet |
| Humidity Range | Up To 95% Non-condensing | Operating Temperature Range | -10°C To 50°C |
| Sensor Type | Photoelectric Sensor | Sensitivity | Meets EN14604 Standards |
| Color | White | Dimensions | Approximately 120 Diameter |
| Usage | Fire Smoke Detection And Alarm | Operating Voltage | DC 3V |
| Highlight | High Reliability Fire Alarm Smoke Detector,Commercial Fire Safety Smoke Detector,Fire Safety Smoke Detector 3V |
||
The JKD-516 is a standalone photoelectric smoke alarm supplied for residential fire safety projects in Europe and other international markets. Manufactured in accordance with EN14604:2005/AC:2008, this model is suitable for distributors, importers and retailers looking for a certified smoke alarm with OEM customization options.
The detector operates using two replaceable AA batteries and requires no mains power, wireless network or gateway. The photoelectric sensor is designed to detect smoke particles commonly produced during the early stages of residential fires, while the built-in sounder delivers an alarm volume of at least 85dB at a distance of three metres.
Whether the project involves wholesale distribution, retail sales or private branding, the JKD-516 provides a practical solution supported by technical documentation and product customization services.
For distributors and importers, working directly with a manufacturing supplier can simplify product development and communication throughout the project.
Our team supports customers with:
- OEM and private-label production
- Product documentation
- Packaging customization
- Multilingual instruction manuals
- Sample evaluation before production
- Technical support during product selection
By working with a single manufacturing source, buyers can keep branding, documentation and production requirements aligned throughout the project.
The detector uses a photoelectric reflection sensor with a specified smoke sensitivity of 0.25dB/m, meeting the technical requirements of residential smoke alarm applications.
Powered by two replaceable AA batteries, the detector operates independently without requiring household electrical wiring.
The built-in sounder produces an alarm of ≥85dB at 3 metres, providing a clear audible warning when smoke is detected.
The detector is designed with an average standby current of less than 50μA and an alarm current below 70μA, helping reduce battery consumption during normal operation.
The unit can be installed on ceilings or walls and is suitable for residential rooms with a maximum recommended coverage area of 40m², depending on room layout and local installation guidance.
The JKD-516 is suitable for supply to:
- Fire safety distributors
- Electrical wholesalers
- DIY retail chains
- Home improvement stores
- Building material importers
- Online retailers
- Security equipment suppliers
- Private-label brands
The product can be customized according to different market requirements, including language versions, packaging design and product identification.
The JKD-516 is manufactured according to EN14604:2005/AC:2008 and can be supplied with supporting documentation for customer review.
Available documents include:
- EN14604 certification or test documentation
- SGS documentation
- UKCA documentation
- RoHS declaration
- Product specification sheet
- User manual
- Product label files
- Packaging drawings
Customers are advised to review the applicable documents before confirming production for their target market.
Smoke alarm EN14604(CPR) Certi.pdf
| Item | Specification |
|---|---|
| Model | JKD-516 |
| Product Type | Standalone Smoke Alarm |
| Standard | EN14604:2005/AC:2008 |
| Sensor | Photoelectric Reflection |
| Power Supply | 2 * 1.5V AA Batteries |
| Smoke Sensitivity | 0.25dB/m |
| Alarm Volume | ≥85dB @ 3m |
| Silence Function | Approx. 10 Minutes |
| Product Life | 10 Years After Manufacture |
| Standby Current | <50μA |
| Alarm Current | <70μA |
| Operating Temperature | -10°C to +50°C |
| Humidity | <95% RH (Non-condensing) |
| Installation | Ceiling / Wall |
| Coverage Area | Up to 40m² |
| Dimensions | Φ120 * 39mm |
| Weight | 180 ±10g |
Yes. We work with distributors, wholesalers, retailers and brand owners on OEM and private-label projects.
Yes. Packaging, labels and instruction manuals can be customized according to your branding requirements.
Yes. Product specifications and applicable compliance documents can be provided for evaluation before production.
The product is manufactured according to EN14604:2005/AC:2008. Buyers should verify any additional regulatory requirements applicable in their destination country.
Yes. Samples are available for testing and project evaluation before placing a bulk order.
If you are looking for a long-term smoke alarm supplier for distribution, retail or OEM projects, contact us with your target market, estimated order quantity and customization requirements. We will prepare a quotation together with the relevant technical documentation and recommended OEM options.
