High Sensitivity 10 Year Smoke Detector OEM ODM Battery Operated Smoke Detectors
| Place of Origin | China |
|---|---|
| Brand Name | Symank |
| Certification | CE/ROHS/SGS/UKCA |
| Model Number | JKD-516 |
| Certificates | Smoke alarm EN14604(CPR) Ce...ti.pdf |
| Minimum Order Quantity | 100pcs |
| Price | Negotiable |
| Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Delivery Time | 5 days |
| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 50K/Month |
| Name | 10 Year Smoke Detector | Powersupply | Battery Operated |
|---|---|---|---|
| Usage | Smoke Detection In Fire Alarm System | Reset Time | Less Than 1 Second |
| Operatingtemperaturerange | -10°C To 50°C | Type | Smoke Detector |
| Humidityrange | 0% To 95% Non-condensing | Voltage | 3V DC |
| Material | ABS | Dimensions | Diameter 12 Cm, Height 4 Cm |
| Detectionmethod | Photoelectric | Environmental Temperature | -10℃ ~ +55℃ |
| Alarmsoundlevel | 85 DB At 10 Feet | Color | White |
| Certifications | SGS Listed, CE Certified | ||
| Highlight | High Sensitivity 10 Year Smoke Detector,Photoelectric Sensor Smoke Alarm,ODM Battery Operated Smoke Detectors |
||
A smoke alarm is one of the most important safety devices in any home. The JKD-516 is designed to provide dependable smoke detection for residential environments by combining photoelectric sensing technology with battery-powered operation.
The detector continuously monitors for smoke and activates an audible alarm when smoke reaches the specified sensitivity level. Because it operates independently using two replaceable AA batteries, the alarm continues to provide protection even during electrical power interruptions.
Manufactured according to EN14604:2005/AC:2008, the JKD-516 is suitable for distributors, retailers and OEM brands supplying residential fire safety products.
Residential fires can develop unexpectedly, whether caused by cooking accidents, electrical faults or unattended appliances. Early smoke detection gives occupants valuable time to respond and evacuate safely.
The JKD-516 is designed for everyday household use with features that support reliable operation and straightforward maintenance. Its standalone design allows installation without wiring or additional equipment, making it suitable for both existing homes and new residential projects.
The detector uses a photoelectric reflection sensor with a smoke sensitivity of 0.25dB/m, providing reliable smoke detection for residential applications.
Powered by 2 * 1.5V AA batteries, the detector remains operational during power failures and allows batteries to be replaced when necessary.
An alarm output of at least 85dB at 3 metres helps alert occupants quickly when smoke is detected.
With a standby current below 50μA, the detector is designed to maximize battery efficiency during normal operation.
Users can verify detector functionality at any time using the test button. The silence function temporarily mutes nuisance alarms for approximately 10 minutes after confirming there is no fire.
The JKD-516 is suitable for installation in:
- Bedrooms
- Living rooms
- Hallways
- Dining rooms
- Apartments
- Family houses
- Holiday homes
- Rental properties
For optimum performance, smoke alarms should be installed according to local fire safety regulations and manufacturer installation instructions.
The JKD-516 offers a balance of compliance, ease of installation and everyday usability. It is suitable for businesses looking to supply a proven residential smoke alarm platform that supports OEM customization and private-label branding.
Our manufacturing team also provides flexible production services for customers requiring customized packaging, multilingual manuals and market-specific labeling.
The JKD-516 is manufactured according to EN14604:2005/AC:2008.
Available documentation includes:
- EN14604 documentation
- SGS reports
- UKCA documentation
- RoHS declaration
- Product specification sheet
- User manual
- Packaging information
Documentation is supplied according to the destination market and final product configuration.
Smoke alarm EN14604(CPR) Certi.pdf Smoke Alarm ROHS Certi.pdf Smoke Alarm UKCA Certi.pdf| Item | Specification |
|---|---|
| Model | JKD-516 |
| Product Type | Smoke Alarm for Home |
| Standard | EN14604:2005/AC:2008 |
| Sensor | Photoelectric Reflection |
| Power Supply | 2 * 1.5V AA Batteries |
| Smoke Sensitivity | 0.25dB/m |
| Alarm Volume | ≥85dB @ 3m |
| Silence Function | Approx. 10 Minutes |
| Product Life | 10 Years After Manufacture |
| Standby Current | <50μA |
| Alarm Current | <70μA |
| Operating Temperature | -10°C to +50°C |
| Humidity | <95% RH (Non-condensing) |
| Installation | Ceiling / Wall |
| Coverage Area | Up to 40m² |
| Dimensions | Φ120 * 39mm |
| Weight | 180 ±10g |
Yes. The detector is designed for residential environments including houses, apartments and holiday homes.
No. It operates using two replaceable AA batteries and can be installed without mains power.
Yes. The detector supports both ceiling and wall installation in accordance with the user manual and local regulations.
Yes. We provide logo printing, packaging customization, multilingual documentation and private-label manufacturing.
Yes. Sample units are available for evaluation and testing before bulk orders.
If you are sourcing smoke alarms for home under your own brand or for wholesale distribution, we can support your project with OEM manufacturing, technical documentation and flexible customization services. Contact us to discuss your target market, certification requirements and expected order volume.