Contact Person : Chung
Phone Number : 8618126273416
Whatsapp : +8618126273416

High Sensitivity 10 Year Smoke Detector OEM ODM Battery Operated Smoke Detectors

Place of Origin China
Brand Name Symank
Certification CE/ROHS/SGS/UKCA
Model Number JKD-516
Certificates Smoke alarm EN14604(CPR) Ce...ti.pdf
Minimum Order Quantity 100pcs
Price Negotiable
Packaging Details Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm
Delivery Time 5 days
Payment Terms L/C,T/T,Western Union
Supply Ability 50K/Month
Product Details
Name 10 Year Smoke Detector Powersupply Battery Operated
Usage Smoke Detection In Fire Alarm System Reset Time Less Than 1 Second
Operatingtemperaturerange -10°C To 50°C Type Smoke Detector
Humidityrange 0% To 95% Non-condensing Voltage 3V DC
Material ABS Dimensions Diameter 12 Cm, Height 4 Cm
Detectionmethod Photoelectric Environmental Temperature -10℃ ~ +55℃
Alarmsoundlevel 85 DB At 10 Feet Color White
Certifications SGS Listed, CE Certified
Highlight

High Sensitivity 10 Year Smoke Detector

,

Photoelectric Sensor Smoke Alarm

,

ODM Battery Operated Smoke Detectors

Leave a Message
Product Description
Smoke Alarm for Home with Photoelectric Smoke Detection

Product Overview

A smoke alarm is one of the most important safety devices in any home. The JKD-516 is designed to provide dependable smoke detection for residential environments by combining photoelectric sensing technology with battery-powered operation.

The detector continuously monitors for smoke and activates an audible alarm when smoke reaches the specified sensitivity level. Because it operates independently using two replaceable AA batteries, the alarm continues to provide protection even during electrical power interruptions.

Manufactured according to EN14604:2005/AC:2008, the JKD-516 is suitable for distributors, retailers and OEM brands supplying residential fire safety products.


Designed for Everyday Home Protection

Residential fires can develop unexpectedly, whether caused by cooking accidents, electrical faults or unattended appliances. Early smoke detection gives occupants valuable time to respond and evacuate safely.

The JKD-516 is designed for everyday household use with features that support reliable operation and straightforward maintenance. Its standalone design allows installation without wiring or additional equipment, making it suitable for both existing homes and new residential projects.


Key Features
Photoelectric Smoke Detection

The detector uses a photoelectric reflection sensor with a smoke sensitivity of 0.25dB/m, providing reliable smoke detection for residential applications.

Battery Powered

Powered by 2 * 1.5V AA batteries, the detector remains operational during power failures and allows batteries to be replaced when necessary.

Loud Audible Alarm

An alarm output of at least 85dB at 3 metres helps alert occupants quickly when smoke is detected.

Low Energy Consumption

With a standby current below 50μA, the detector is designed to maximize battery efficiency during normal operation.

Test and Silence Button

Users can verify detector functionality at any time using the test button. The silence function temporarily mutes nuisance alarms for approximately 10 minutes after confirming there is no fire.


Recommended Installation Areas

The JKD-516 is suitable for installation in:

  • Bedrooms
  • Living rooms
  • Hallways
  • Dining rooms
  • Apartments
  • Family houses
  • Holiday homes
  • Rental properties

For optimum performance, smoke alarms should be installed according to local fire safety regulations and manufacturer installation instructions.


Why Choose the JKD-516?

The JKD-516 offers a balance of compliance, ease of installation and everyday usability. It is suitable for businesses looking to supply a proven residential smoke alarm platform that supports OEM customization and private-label branding.

Our manufacturing team also provides flexible production services for customers requiring customized packaging, multilingual manuals and market-specific labeling.


Certification & Documentation

The JKD-516 is manufactured according to EN14604:2005/AC:2008.

Available documentation includes:

  • EN14604 documentation
  • SGS reports
  • UKCA documentation
  • RoHS declaration
  • Product specification sheet
  • User manual
  • Packaging information

Documentation is supplied according to the destination market and final product configuration.

Smoke alarm EN14604(CPR) Certi.pdf Smoke Alarm ROHS Certi.pdf Smoke Alarm UKCA Certi.pdf
Technical Specifications
Item Specification
Model JKD-516
Product Type Smoke Alarm for Home
Standard EN14604:2005/AC:2008
Sensor Photoelectric Reflection
Power Supply 2 * 1.5V AA Batteries
Smoke Sensitivity 0.25dB/m
Alarm Volume ≥85dB @ 3m
Silence Function Approx. 10 Minutes
Product Life 10 Years After Manufacture
Standby Current <50μA
Alarm Current <70μA
Operating Temperature -10°C to +50°C
Humidity <95% RH (Non-condensing)
Installation Ceiling / Wall
Coverage Area Up to 40m²
Dimensions Φ120 * 39mm
Weight 180 ±10g

Frequently Asked Questions
Is the JKD-516 suitable for home use?

Yes. The detector is designed for residential environments including houses, apartments and holiday homes.

Does the detector require electrical wiring?

No. It operates using two replaceable AA batteries and can be installed without mains power.

Can the alarm be installed on a wall?

Yes. The detector supports both ceiling and wall installation in accordance with the user manual and local regulations.

Is OEM customization available?

Yes. We provide logo printing, packaging customization, multilingual documentation and private-label manufacturing.

Can samples be provided before mass production?

Yes. Sample units are available for evaluation and testing before bulk orders.


Request a Quotation

If you are sourcing smoke alarms for home under your own brand or for wholesale distribution, we can support your project with OEM manufacturing, technical documentation and flexible customization services. Contact us to discuss your target market, certification requirements and expected order volume.