Advanced Photoelectric Smoke Alarm Device EN14604 SGS Tested Professional OEM Supply
| Place of Origin | China |
|---|---|
| Brand Name | Symank |
| Certification | CE/SGS/ROHS/UKCA |
| Model Number | JKD-517 |
| Certificates | Smoke alarm EN14604(CPR) Ce...ti.pdf |
| Minimum Order Quantity | 100pcs |
| Price | Negotiable |
| Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Delivery Time | 5 days |
| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 50K/Month |
| Name | Fire Alarm Smoke Detector | Weight | 180 Grams |
|---|---|---|---|
| Test Button | Yes, For Manual Testing | Humidity Range | 10% To 95% RH |
| Material | ABS | Power Source | Battery Operated |
| Detection Type | Photoelectric | Temperature Range | -10°C To 50°C |
| Operating Voltage | DC 3V | Usage | Fire Detection And Alarm System |
| Environmental Temperature | -10℃ ~ +55℃ | Sensitivity | Meets EN14604 Standards |
| Color | White | Reset Time | Less Than 1 Second |
| Highlight | photoelectric smoke alarm EN14604,fire alarm smoke detector SGS tested,smoke detector device OEM supply |
||
The JKD-517 is a standalone smoke alarm designed for residential fire detection. Operating independently without mains power, Wi-Fi or smart home connectivity, it provides continuous smoke monitoring using a photoelectric sensing chamber and an integrated audible alarm.
Powered by two replaceable 1.5V AA batteries, the detector continues to operate even during power outages, making it suitable for homes, apartments, holiday properties and residential renovation projects. When smoke reaches the specified alarm threshold of 0.25dB/m, the detector activates an alarm of at least 85dB at 3 metres.
Manufactured according to EN14604:2005/AC:2008, the JKD-517 is available for distributors, wholesalers and private-label brands seeking a reliable standalone smoke alarm for the European market.
Standalone smoke alarms remain one of the most widely used fire safety solutions in residential buildings because they operate independently and do not rely on an external control panel or internet connection.
The JKD-517 is particularly suitable for projects where simple installation, straightforward maintenance and compliance with residential smoke alarm requirements are the main priorities.
For distributors, standalone alarms also offer broad market acceptance because they can be installed in both new homes and existing buildings without additional infrastructure.
The detector functions as a standalone unit, requiring no gateway, wireless hub or external controller.
The photoelectric reflection sensor is designed to detect visible smoke particles associated with many slow-developing household fires.
Powered by 2 * 1.5V AA batteries, the detector allows batteries to be replaced during its service life.
An alarm output of ≥85dB at 3 metres provides a clear warning when smoke is detected.
The detector has a standby current of less than 50μA and an alarm current of less than 70μA, supporting efficient battery operation.
A combined test and silence button enables users to verify correct operation and temporarily mute nuisance alarms for approximately 10 minutes after confirming there is no fire hazard.
The JKD-517 is suitable for a variety of residential environments, including:
- Houses
- Apartments
- Bedrooms
- Living rooms
- Hallways
- Holiday homes
- Rental properties
- Student accommodation
- Small residential buildings
The detector supports ceiling or wall installation and is recommended for rooms with a maximum coverage area of 40m², depending on local installation guidance.
The JKD-517 is manufactured according to EN14604:2005/AC:2008, the European standard for standalone residential smoke alarms.
Supporting documentation available upon request includes:
- EN14604 documentation
- SGS reports
- UKCA documentation
- RoHS declaration
- Product specification sheet
- User manual
- Product label artwork
Customers should verify all documentation against the final product configuration before placing bulk orders.
Smoke alarm EN14604(CPR) Certi.pdf
| Item | Specification |
|---|---|
| Model | JKD-517 |
| Product Type | Standalone Smoke Alarm |
| Standard | EN14604:2005/AC:2008 |
| Sensor | Photoelectric Reflection |
| Power Supply | 2 * 1.5V AA Batteries |
| Smoke Sensitivity | 0.25dB/m |
| Alarm Volume | ≥85dB @ 3m |
| Silence Function | Approx. 10 Minutes |
| Product Life | 10 Years After Manufacture |
| Standby Current | <50μA |
| Alarm Current | <70μA |
| Operating Temperature | -10°C to +50°C |
| Humidity | <95% RH (Non-condensing) |
| Installation | Ceiling / Wall |
| Coverage Area | Up to 40m² |
| Dimensions | Φ120 * 39mm |
| Weight | 180 ±10g |
The JKD-517 is available for OEM and private-label manufacturing. We support:
- Logo printing
- Product label customization
- Retail packaging design
- Multilingual user manuals
- Barcode labels
- Outer carton printing
- OEM model identification
All artwork is reviewed before production to ensure compliance with the approved product documentation and certification markings.
No. It is a standalone smoke alarm and operates independently without Wi-Fi, Zigbee or any mobile application.
Yes. The detector uses two standard AA batteries that can be replaced when required.
Yes. It is designed for residential fire detection and manufactured according to EN14604:2005/AC:2008.
Yes. OEM branding, customized packaging and multilingual documentation are available for qualified orders.
Yes. Samples are available for product evaluation before confirming volume production.
If you are looking for a standalone smoke alarm for wholesale distribution, retail programs or OEM manufacturing, contact us with your target market and project requirements. We will prepare a quotation together with the applicable technical documentation and customization options.