Contact Person : Chung
Phone Number : 8618126273416
Whatsapp : +8618126273416

10 Year Smoke and Carbon Monoxide Alarm for European Home Safety

Place of Origin CN
Brand Name Symank
Certification CE/ROHS/SGS
Model Number JKD-513COM
Certificates CE EN50291 Report.pdf
Minimum Order Quantity 100pcs
Price Negotiable
Packaging Details Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm
Delivery Time 5 days
Payment Terms L/C,D/P,T/T
Supply Ability 50K/month
Product Details
Size Diameter 120 Mm, Height 40 Mm Battery Life Up To 10 Years
Type Photoelectric / Ionization / Dual Sensor Reset Time Less Than 1 Second
Sensor Life 10 Years Color Light Grey
Alarm Current ≥60mA,69mA Alarm Sound Level 85 DB At 10 Feet
Powersupply Battery Operated Power Supply Battery Operated
Operatingvoltage 3V DC Weight Approx. 150 Grams
Test Button Yes Installation Type Ceiling Mount
Highlight

smart smoke carbon monoxide detector

,

high-performance smoke detector

,

battery-operated CO detector

Leave a Message
Product Description
10 Year Smoke and Carbon Monoxide Alarm with Dual EN Standards
One Product Life Cycle for Long Term Home Safety

Residential safety products are not purchased for a few months of use. They are expected to remain part of a home safety system for years.

The JKD-513COM smoke and carbon monoxide alarm is designed around a 10-year product life after manufacture, giving distributors and residential safety brands a long-term product platform rather than a short-life entry-level alarm.

The core purchasing reason for this JKD-513COM is therefore its 10-year lifecycle combined with certified smoke and CO protection.

It integrates a photoelectric smoke sensor and an electrochemical CO sensor in one housing while meeting the requirements of both EN14604:2005/AC:2008 and EN50291-1:2018.

For European importers, wholesalers and private-label brands, this creates a straightforward proposition:

10-year product life, two residential hazards and two corresponding EN standards in one alarm.

Why a 10 Year Product Life Matters

A long product lifecycle can be valuable throughout the distribution chain.

For homeowners, it provides a clearly defined replacement cycle.

For retailers, a 10 year smoke and CO alarm can be positioned above basic short-life products.

For distributors, it creates a long-term product category suitable for residential safety portfolios.

For private-label brands, the 10-year specification also provides a clear feature that can be communicated through packaging, product listings and technical documentation.

JKD-513COM is therefore suitable for buyers looking beyond the lowest initial purchase price and focusing instead on long-term residential use.

Smoke and Carbon Monoxide Protection in One Alarm

A home may face more than one type of hazard.

JKD-513COM combines:

  • Smoke Alarm Function
  • Carbon Monoxide Alarm Function

inside one compact product.

The two functions use different sensing technologies because smoke and CO require different detection principles.

For smoke, JKD-513COM uses a:

  • Photoelectric Reflection Sensor

For carbon monoxide, it uses an:

  • Electrochemical CO Sensor

This allows the product to serve as a combination smoke and CO alarm while retaining dedicated sensing technology for each hazard.

Photoelectric Smoke Alarm with 0.25dB per Meter Sensitivity

The smoke sensing system has a specified sensitivity of:

  • 0.25dB/m

Photoelectric reflection technology provides the sensing basis for the smoke alarm function.

JKD-513COM also includes an approximately:

  • 10-minute smoke alarm silence function

This provides practical everyday usability in residential environments.

For buyers searching for a photoelectric smoke alarm for home use, JKD-513COM combines this smoke sensing technology with carbon monoxide monitoring in the same unit.

Electrochemical Carbon Monoxide Sensor

The CO monitoring function uses an electrochemical carbon monoxide sensor and conforms to EN50291-1:2018.

The specified alarm response is:

CO Level Alarm Response
50ppm Within 60 to 90 minutes
100ppm Within 10 to 40 minutes
300ppm Within 3 minutes

These defined response levels give technical buyers measurable information when evaluating a residential carbon monoxide alarm.

Rather than describing the CO sensor simply as sensitive, the product provides specific response behavior at different carbon monoxide concentrations.

EN14604 and EN50291 in One Product

One of the strongest advantages of JKD-513COM for the European market is the combination of two relevant product standards.

EN14604:2005/AC:2008

Supports the smoke alarm function.

EN50291-1:2018

Supports the carbon monoxide alarm function.

This makes JKD-513COM particularly suitable for buyers searching for an EN14604 smoke alarm and EN50291 CO alarm in one combined product.

It is also supported by SGS certification, providing professional distributors with third-party certification documentation for product evaluation.

RoHS EMC and UKCA Compliance

In addition to the main smoke and CO standards, JKD-513COM is supported by:

  • RoHS
  • EMC
  • UKCA

For importers and private-label customers, this broader documentation package can support supplier qualification, internal product assessment and market preparation.

The combination of SGS, EN14604, EN50291, RoHS, EMC and UKCA is therefore an important B2B purchasing consideration.

Replaceable AA Battery Power

JKD-513COM is powered by:

  • 3 x 1.5V AA alkaline batteries

The replaceable battery design provides a familiar power solution for residential users.

This gives the model a different position from a sealed lithium 10 year smoke and carbon monoxide alarm.

Consumers who prefer standard replaceable batteries can retain control over the power source during the product lifecycle while benefiting from a detector platform designed for 10 years of service.

The average standby current is:

  • Less than 50μA

and the average alarm current is:

  • Less than 70mA.
Audible and Visual Warning

JKD-513COM is a Type B apparatus, designed to provide visual and audible alarm indications.

The specified alarm sound level is:

  • At least 85dB at 3 meters

This provides a clear warning when an applicable smoke or CO alarm condition occurs.

The product can therefore be marketed as both a home smoke alarm and a residential CO alarm, while providing the convenience of one combined unit.

Ceiling or Wall Installation

JKD-513COM supports:

  • Ceiling Installation
  • Wall Installation

The specified detection range is:

  • Maximum 40m² within a room

Its dimensions are approximately:

  • Φ105 x 39mm

with a net weight of:

  • 180 plus or minus 10g.

The compact format is suitable for houses, apartments, rental properties and other residential environments where combined smoke and CO monitoring is required.

A Useful Long Life SKU for Distributors

For distributors, JKD-513COM can fill an important position between basic alarms and sealed-lithium models.

Its selling points are easy to communicate:

  • 10 Year Product Life
  • Smoke and CO in One Alarm
  • EN14604 and EN50291
  • SGS Certification
  • Replaceable AA Battery Power

This makes the product suitable for fire safety wholesalers, electrical distributors, home improvement retailers, residential safety brands and private-label programs.

OEM and ODM support can include customized branding, product labels, retail packaging, multilingual manuals and carton customization.

Technical Specifications
Technical Item Specification
Model JKD-513COM
Product Type Smoke and Carbon Monoxide Alarm
Product Life 10 Years After Manufacture
Power Supply 3 x 1.5V AA Alkaline Batteries
Type of Apparatus Type B Visual and Audible Alarm Only
Smoke Sensor Photoelectric Reflection
Smoke Alarm Sensitivity 0.25dB/m
Smoke Silence Time About 10 Minutes
Smoke Standard EN14604:2005/AC:2008
CO Sensor Electrochemical
CO Standard EN50291-1:2018
50ppm CO Response 60 to 90 Minutes
100ppm CO Response 10 to 40 Minutes
300ppm CO Response Within 3 Minutes
Standby Current Less Than 50μA Average
Alarm Current Less Than 70mA Average
Alarm Method Visual and Audible Alarm
Alarm Sound At Least 85dB at 3m
Operating Temperature -10°C to +50°C
Operating Humidity Less Than 95 Percent RH Non Condensing
Storage Temperature -10°C to +50°C
Storage Humidity Less Than 95 Percent RH Non Condensing
Installation Location Ceiling or Wall
Detection Coverage Maximum 40m² Within a Room
Dimensions Approx. Φ105 x 39mm
Weight 180 Plus or Minus 10g
Certification SGS
Additional Compliance RoHS EMC UKCA
OEM Supported
ODM Supported
Private Label Supported
Certifications and Compliance

JKD-513COM is supported by a complete certification and compliance package for professional buyers:

  • SGS Certification
  • EN14604:2005/AC:2008 Smoke Alarm Standard
  • EN50291-1:2018 Carbon Monoxide Alarm Standard
  • RoHS
  • EMC
  • UKCA

Technical datasheets, product specifications, user manuals and applicable certification documents can be provided for B2B product evaluation.

CE EN50291 Report.pdf

CE EN14604(CPR) Report.pdf

Frequently Asked Questions
How long is the product life of JKD-513COM?

The specified product life is 10 years after manufacture.

Is this a smoke alarm and carbon monoxide alarm in one unit?

Yes. JKD-513COM combines photoelectric smoke sensing and electrochemical CO sensing in one housing.

What smoke standard does it comply with?

The smoke alarm function complies with EN14604:2005/AC:2008.

What standard applies to the CO sensor?

The carbon monoxide function complies with EN50291-1:2018.

Is JKD-513COM SGS certified?

Yes. The model is supported by SGS certification.

What batteries does the alarm use?

It uses 3 x 1.5V AA alkaline batteries.

What is the alarm sound level?

The specified audible warning is at least 85dB at 3 meters.

What is the maximum room coverage?

The specified detection coverage is maximum 40m² within one room.

Is private label production available?

Yes. OEM, ODM and private-label projects are supported.