Contact Person : Chung
Phone Number : 8618126273416
Whatsapp : +8618126273416

Portable Battery Operated Gas Alarm CE Listed Combustible Gas Alarm With CH4 C3H8 Detection

Place of Origin China
Brand Name Symank
Certification CE/ROHS/UKCA
Model Number JKD-831
Certificates Gas alarm EN50194 Certi.pdf
Minimum Order Quantity 100pcs
Price Negotiable
Packaging Details Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm
Delivery Time 5 days
Payment Terms L/C,T/T,Western Union
Supply Ability 50K/Month
Product Details
Name Battery Operated Gas Alarm Weight 200 Grams
Item Porable Gas Detector Humidity Range 10% To 95% Non-condensing
Operating Temperature Range -10°C To 50°C Reset Time Less Than 1 Second
Sensor Type Semiconduct Sensor Sensitivity Meets EN 50194 Standards
Environmental Temperature -10℃ ~ +50℃ Power Source Battery OPERATED
Certifications CE Listed, UKCA Compliant Material ABS Plastic
Battery Life Up To 3 Years
Highlight

Portable Battery Operated Gas Alarm

,

CE Listed Combustible Gas Alarm

,

Combustible Gas Alarm Portable

Leave a Message
Product Description
Cordless LPG Gas Detector with Flexible Battery Powered Installation

Install the Gas Detector Where It Should Be — Not Where the Power Socket Happens to Be

A residential gas detector has an important installation requirement: its position needs to take the characteristics of the target gas into consideration.

For LPG and propane detection, this matters because propane is heavier than air and can accumulate at lower levels when released.

But conventional plug-in LPG gas detectors introduce another consideration:

Where is the electrical outlet?

The technically appropriate detector location and the convenient power outlet location are not always the same.

The JKD-831 Cordless LPG Gas Detector is designed to remove this limitation.

Powered by 2 * CR17505 lithium batteries, the detector does not require a permanent AC outlet or power cable during normal operation. This gives users greater freedom to select an appropriate installation position according to the supplied instructions and applicable requirements.

That is the central reason to choose JKD-831:

The detector location is not dictated by the location of an AC socket.

For distributors and home safety brands, this provides a clear and easily understandable difference from conventional plug-in propane alarms.


What Makes JKD-831 Special?

JKD-831 is not simply an LPG version of another ordinary household gas alarm.

Its defining combination is:

LPG / Propane Detection + Lithium Battery + Cordless Installation

Many traditional propane gas detectors rely on mains power.

That can create practical restrictions:

  • An AC socket must be available
  • The detector may need to be installed close to the outlet
  • A visible power cable may be required
  • Product placement may become less flexible

JKD-831 avoids these limitations through its independent lithium battery power system.

For a professional buyer, this provides a genuine product differentiation rather than simply a different housing or model number.


Dedicated LPG and Propane Detection

The JKD-831 is specifically designed for:

Propane (C3H8)

making it the LPG/propane model within the battery-powered gas detector series.

This gives the product a very clear market position:

  • LPG Gas Detector
  • Propane Gas Detector
  • LPG Leak Detector
  • Propane Leak Alarm
  • LPG Gas Sensor
  • Propane Gas Sensor
  • Home LPG Detector
  • Residential Propane Alarm
  • Battery Powered LPG Detector
  • Cordless Propane Detector

For customers specifically serving LPG-oriented markets, this dedicated positioning can be easier to communicate than a broadly described generic combustible gas product.


Why Cordless Installation Matters for LPG Detection

The physical characteristics of the target gas should always be considered when determining detector placement.

Propane has a higher vapor density than air, so correct installation position is important for effective LPG monitoring.

A plug-in product can sometimes introduce a practical conflict:

The detector should be installed in one position, but the available socket is somewhere else.

With JKD-831, the power supply does not determine the detector's location.

Because the unit is battery powered, users can focus on selecting an appropriate installation position according to:

  • Product instructions
  • Target gas characteristics
  • Room configuration
  • Applicable local requirements

This is the strongest practical benefit of the JKD-831's cordless architecture.


Powered by 2 * CR17505 Lithium Batteries

The JKD-831 operates from:

DC 6.0V

using:

2 * CR17505 Lithium Batteries

No permanent AC mains connection is required for normal operation.

For users, this means:

  • No AC outlet required
  • No power cable required
  • No plug position restriction
  • Cleaner installation
  • More flexible product placement
  • Independent battery operation

For distributors, it creates a simple retail message:

Battery Powered LPG Protection Without an AC Socket

Low Working Current for Battery Powered Operation

A continuously operating gas leak sensor requires efficient power management when running from batteries.

JKD-831 has a specified:

Working Current: ≤150μA

and:

Power Consumption: ≤0.3W

The low-power architecture supports its battery-powered design and distinguishes the product from traditional mains-powered residential gas alarms.

This is particularly important because battery operation is not an accessory feature of JKD-831—it is fundamental to the product design.


10%LEL Alarm Setting

The JKD-831 provides a specified alarm setting value of:

10%LEL

with a detection range of:

0–20%LEL

and repeatability error of:

3%LEL

LEL means Lower Explosive Limit, a commonly used measurement when evaluating combustible gas concentrations.

When the propane concentration reaches the specified alarm condition, the detector activates its audible and visual warning.

For B2B buyers, these clearly defined values provide important technical information when comparing different LPG leak alarms.


Response Time ≤30 Seconds

The JKD-831 has a specified response time of:

≤30 Seconds

Response time is an important technical parameter for any residential combustible gas detector.

When the relevant gas concentration reaches the detection condition, the detector responds and provides a warning through its sound and light alarm system.


Audible + Visual Warning

When an alarm condition occurs, JKD-831 provides:

Sound Alarm + LED Light Indication

The specified alarm sound pressure is:

≥80dB at 1 Meter Ahead

This combination gives users two clear forms of warning:

Audible: a strong sound warning.

Visual: LED indication.

For residential applications, this provides a simple alarm method that users can easily understand.


Automatic Reset for Convenient Daily Use

JKD-831 uses an:

Automatic Reset

When the gas concentration returns to an appropriate level after an alarm event, the detector can automatically return to its normal monitoring condition.

This reduces unnecessary manual operation and makes the home propane detector easier to use in everyday residential environments.


Five-Year Sensor Life

The specified sensor life is:

5 Years

A defined sensor service life gives both distributors and end users a clearer understanding of the product lifecycle.

For professional buyers, this helps with:

  • Replacement planning
  • Product documentation
  • Retail information
  • User manual preparation
  • After-sales communication
  • Portfolio management

The five-year sensor life also provides a clear technical specification for product comparison.


Compact 96 * 96 * 34mm Housing

Removing the AC cable does not require a bulky product design.

JKD-831 measures:

96 * 96 * 34mm

with an approximate weight of:

170g

The compact square housing makes it suitable for residential environments, while the cordless design helps provide a cleaner installation appearance.

This combination is particularly attractive for home safety brands looking for products that combine practical functionality with straightforward residential installation.


Battery Powered vs Plug-in LPG Detector

The difference becomes particularly clear when JKD-831 is compared with a conventional AC gas detector.

Feature JKD-831 Conventional Plug-in LPG Detector
Power Supply Lithium Battery AC Mains
Battery 2 * CR17505
AC Outlet Required No Yes
Permanent Power Cable No Yes
Installation Limited by Socket No Potentially
Main Gas LPG / Propane Model Dependent
Alarm Setting 10%LEL Model Dependent
Detection Range 0–20%LEL Model Dependent
Response Time ≤30s Model Dependent
Alarm Sound + Light Model Dependent
Sensor Life 5 Years Model Dependent

The purpose is not to claim that battery power is always better than AC power.

Instead, JKD-831 gives distributors another solution for customers whose installation requirements make a cordless gas detector more practical.


A Clear Buying Reason for Retail Customers

For distributors, products are easier to sell when the main advantage can be explained in one sentence.

For JKD-831, that sentence is:

“Install your LPG detector without depending on an electrical outlet."

This is much easier for retailers and consumers to understand than a long list of technical parameters.

The specifications then support that core benefit:

2 * CR17505 Lithium Batteries
→ Cordless operation

≤150μA Working Current
→ Low-power battery architecture

Propane C3H8 Detection
→ Dedicated LPG application

10%LEL Alarm Setting
→ Defined combustible gas warning point

≤30s Response
→ Clearly specified response performance

5-Year Sensor Life
→ Defined product lifecycle

Every technical feature supports the central positioning rather than competing with it.


Who Should Buy JKD-831?

JKD-831 is particularly relevant for professional customers targeting residential LPG markets.

Potential buyers include:

  • LPG equipment distributors
  • Gas safety distributors
  • Home safety brands
  • Fire safety wholesalers
  • Gas appliance distributors
  • Electrical wholesalers
  • DIY retailers
  • Home improvement retailers
  • Importers
  • Private-label alarm brands

It can also complement conventional AC gas alarms, giving distributors both plug-in and battery-powered gas detection options.


A Different Product from JKD-829

Although JKD-829 and JKD-831 share a similar battery-powered architecture, they serve different gas applications.

Model Power Main Detection
JKD-829 2 * CR17505 Lithium Batteries Natural Gas
JKD-831 2 * CR17505 Lithium Batteries LPG / Propane C3H8

This makes it possible for distributors to build a two-model battery-powered gas detector range:

JKD-829 — Battery Natural Gas Detector
JKD-831 — Battery LPG / Propane Detector

Rather than forcing one model to cover every application, each product can be positioned clearly according to its intended gas type.


OEM, ODM & Private Label LPG Detector

JKD-831 can be customized for professional B2B customers.

Available services include:

  • OEM LPG Gas Detector
  • OEM Propane Detector
  • ODM Project Support
  • Private Label Gas Detector
  • Custom Logo Printing
  • Product Label Customization
  • Retail Packaging Design
  • Multilingual User Manuals
  • Barcode Customization
  • Master Carton Customization

This allows customers to build their own battery powered LPG detector range without developing the product platform from the beginning.


Manufacturing & Quality Control

Consistent manufacturing and inspection are essential for residential gas detection products.

JKD-831 production and quality control can include:

  • Incoming material inspection
  • PCB inspection
  • Battery supply verification
  • Working current inspection
  • Sensor installation
  • Gas detection testing
  • Alarm setting verification
  • Response function testing
  • LED indicator inspection
  • Sound alarm testing
  • Automatic reset verification
  • Appearance inspection
  • Final product inspection
  • Packaging inspection

These procedures help maintain stable product quality across production batches.


Technical Specifications
Specification JKD-831
Model JKD-831
Product Type Cordless / Battery Powered LPG Gas Detector
Main Detected Gas Propane (C3H8)
Application LPG / Propane Detection
Power Supply DC 6.0V
Battery Type 2 * CR17505 Lithium Batteries
Power Consumption ≤0.3W
Working Current ≤150μA
Alarm Setting Value 10%LEL
Detection Range 0–20%LEL
Repeatability Error 3%LEL
Response Time ≤30 Seconds
Display Mode LED Indicator Light
Alarm Method Sound & Light Alarm
Alarm Sound Pressure ≥80dB at 1m Ahead
Reset Method Automatic Reset
Sensor Life 5 Years
Operating Temperature -10°C to +55°C
Relative Humidity ≤95% RH, No Condensation
Atmospheric Pressure 86kPa–106kPa
Dimensions 96 * 96 * 34mm
Weight Approx. 170g
Operating Environment Indoor Residential Use
OEM Supported
ODM Supported
Private Label Supported
Logo Customization Supported
Packaging Customization Supported

Technical Documentation

Professional buyers can request relevant product documentation for evaluation.

Available documents can include:

  • Product Technical Datasheet
  • Product Specification
  • User Manual
  • Available Compliance Documentation
Document Downloads

Gas alarm EN50194 Certi.pdf


Gas Alarm UKCA Certi.pdf


Gas Alarm ROHS Certi.pdf


Frequently Asked Questions
What is the biggest advantage of JKD-831?

Its biggest advantage is cordless battery-powered installation. Two CR17505 lithium batteries allow the detector to operate without depending on an AC outlet.

What gas does JKD-831 detect?

JKD-831 is designed for LPG / propane (C3H8) detection.

Is JKD-831 a natural gas detector?

No. JKD-831 is the LPG/propane model. JKD-829 is the corresponding battery-powered natural gas model.

Does the detector require an AC socket?

No. JKD-831 operates from DC 6.0V using two CR17505 lithium batteries.

What is the alarm setting value?

The specified alarm setting is 10%LEL.

What is the detection range?

The specified range is 0–20%LEL.

What is the response time?

The specified response time is ≤30 seconds.

How loud is the alarm?

The specified alarm sound pressure is ≥80dB at 1 meter ahead.

Does it reset automatically?

Yes. The specified reset method is automatic reset.

What is the sensor life?

The specified sensor life is 5 years.

Can you manufacture the product under our brand?

Yes. OEM, ODM and private-label services can include logo, product label, packaging and user manual customization.