OEM ODM Home Methane Detector EN50194 Approved Methane Gas Detectors With Dual Gas Detection
| Place of Origin | China |
|---|---|
| Brand Name | Symank |
| Certification | CE/ROHS/SGS/UKCA |
| Model Number | JKD-838 |
| Certificates | Gas alarm EN50194 Certi.pdf |
| Minimum Order Quantity | 100pcs |
| Price | Negotiable |
| Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Delivery Time | 5 days |
| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 50K/Month |
| Name | Home Methane Detector | Productname | Gas Leak Alarm |
|---|---|---|---|
| Operatingtemperaturerange | -10°C To 50°C | Sensortype | Semiconductor Sensor |
| Weight | Approx. 200 Grams | Certifications | CE, SGS, RoHS |
| Resetmethod | Manual Reset Button | Alarmoutput | Sound And LED Indicator |
| Responsetime | ≤10 Seconds | Self-Diagnosisfunction | Yes, Sensor Fault Detection |
| Detectiongastype | Combustible Gases (e.g., LPG, Methane, Propane) | Operatinghumidityrange | 10% To 90% RH (non-condensing) |
| Powersupply | AC 110-220V Or DC 9V Battery | Dimensions | Approx. 120mm X 75mm X 40mm |
| Alarmsoundlevel | ≥85 DB At 1 Meter | Installationtype | Wall-mounted Or Tabletop |
| Highlight | OEM Home Methane Detector,ODM Home Methane Detector,EN50194 Approved Methane Gas Detectors |
||
When distributors and safety brands source a combustible gas detector, price and appearance are only part of the purchasing decision. For professional residential safety markets, applicable standards, third-party testing, sensor technology and stable manufacturing are equally important.
The JKD-838 EN50194 Combustible Gas Detector is developed for indoor residential gas monitoring and is suitable for natural gas and LPG applications. It combines a catalytic sensing system with AC-powered continuous operation, audible and visual warnings and a five-year maximum sensor lifetime.
For European buyers, one of its strongest advantages is compliance with EN50194-1:2009, supported by SGS certification.
The detector operates from AC 100–240V, 50Hz, with European, US and Australian plug versions available. This gives importers and private-label brands a flexible residential gas alarm platform that can be adapted to different international markets.
When sourcing a home gas detector for the European market, professional buyers frequently look beyond basic specifications and evaluate the applicable product standard.
The JKD-838 is manufactured according to:
and supported by:
This is a major selling point for distributors that require documented products rather than generic gas leak alarms with limited compliance support.
For professional buyers, the certification package helps with:
- Internal product evaluation
- Technical documentation review
- Supplier qualification
- Product portfolio planning
- Distributor product presentation
- Customer compliance inquiries
For this reason, the JKD-838 is particularly suitable for customers searching for an EN50194 gas detector or SGS certified gas alarm.
Natural gas is widely used in residential properties for cooking and heating.
Since methane (CH4) is the principal component of natural gas, methane detection is an important part of residential natural gas safety.
The specified detection gas of JKD-838 is:
This allows the detector to be positioned in the market under several relevant product terms:
- Natural Gas Detector
- Methane Detector
- CH4 Gas Detector
- Natural Gas Leak Alarm
- Methane Gas Sensor
- Residential Natural Gas Alarm
- Home Gas Leak Detector
- Combustible Gas Detector
This broader terminology is also valuable for SEO because professional buyers do not always use the same search phrase when sourcing the same type of product.
The JKD-838 platform can also be supplied for LPG detection applications.
LPG is commonly used in residential environments where bottled or tank-supplied gas is preferred. For distributors serving these markets, an LPG gas detector is an important addition to a complete home safety portfolio.
Relevant product positioning can include:
- LPG Gas Detector
- LPG Leak Detector
- LPG Gas Alarm
- Home LPG Detector
- Residential LPG Alarm
- Flammable Gas Detector
- Combustible Gas Sensor
- Household Gas Leak Alarm
The ability to address both natural gas and LPG applications makes JKD-838 more flexible for international distributors.
The sensing element is at the heart of every reliable gas leakage detector.
JKD-838 uses a:
Catalytic sensing technology is designed for combustible gas monitoring and provides a practical solution for residential applications.
The detector uses:
Surrounding air reaches the sensor naturally without an external sampling pump. The sensor continuously monitors the environment and triggers the alarm system when the defined gas concentration is reached.
This simple detection architecture supports stable continuous operation for household applications.
JKD-838 has a specified alarm concentration of:
LEL refers to the Lower Explosive Limit, an important measurement used when describing combustible gas concentrations.
When the target gas reaches the specified alarm condition, the detector activates its audible and visual warning.
For professional buyers, clearly defined LEL performance is an important parameter when comparing different flammable gas detectors and residential gas sensors.
Unlike the lithium battery models in the product range, JKD-838 is designed for continuous mains-powered operation.
This makes the JKD-838 a practical plug-in gas detector for permanent residential installations.
Advantages of AC operation include:
- Continuous mains power
- No routine battery replacement
- Simple plug-in installation
- No separate power adapter required
- Suitable for permanent monitoring
- Wide AC input voltage
- Multiple plug configurations available
For customers who specifically prefer battery-powered gas detection, separate lithium battery models are available, while JKD-838 serves the traditional AC-powered segment.
International distributors often sell into markets with different plug systems.
The JKD-838 can be supplied with:
- EU Plug
- US Plug
- AU Plug
Combined with its AC 100–240V input, these options make it easier for B2B customers to adapt the same product platform for different regions.
This is particularly useful for private-label brands selling safety products across multiple markets.
An effective gas safety alarm must provide a clear warning once an alarm condition occurs.
The JKD-838 provides:
with an alarm volume of:
The audible warning is supported by visual alarm indication, helping users quickly recognize the detector's alarm status.
This combination provides a straightforward warning method for residential users.
The catalytic sensor has a specified maximum lifetime of:
For distributors and private-label brands, a defined sensor lifetime provides useful information for:
- Product lifecycle management
- Replacement recommendations
- After-sales planning
- User manual preparation
- Retail product information
- Customer communication
The five-year sensor specification also provides a clear distinction between the sensor service life and the detector's everyday AC power supply.
The JKD-838 is an indoor-use gas detection device.
Its specified operating environment includes:
| Environmental Parameter | Specification |
|---|---|
| Operating Temperature | -10°C to +50°C |
| Relative Humidity | ≤95%, Non-condensing |
| Atmospheric Pressure | 86kPa–106kPa |
| Application Type | Indoor Use |
Potential residential applications include:
- Home kitchens
- Apartments
- Houses
- Villas
- Residential buildings
- Rental properties
- Holiday homes
- Indoor natural gas applications
- Indoor LPG applications
Detector placement should follow the user manual and the requirements of the target gas.
The JKD-838 measures:
with a weight of approximately:
The housing integrates the gas sensing system, AC power components and audible/visual warning functions into a compact residential unit.
For distributors, the compact size also helps simplify retail packaging and transportation.
Many professional safety distributors already sell smoke detectors and carbon monoxide alarms. Adding a combustible gas detector allows them to provide a more complete household safety portfolio.
The JKD-838 can complement product categories such as:
- Smoke Detectors
- Carbon Monoxide Detectors
- CO + Smoke Alarms
- CO + Gas Detectors
- Natural Gas Detectors
- LPG Detectors
This makes it suitable for established safety distributors as well as brands expanding into residential gas detection.
The JKD-838 is designed for professional sourcing and can serve customers including:
- Gas detector distributors
- Fire safety wholesalers
- Electrical wholesalers
- Security product distributors
- Home safety brands
- DIY retailers
- Gas appliance distributors
- Building safety suppliers
- Importers
- Private-label brands
For these buyers, the strongest purchasing combination is:
This creates a clear product story that is easy for distributors to communicate to their own customers.
We support international customers with flexible OEM, ODM and private-label manufacturing.
Customization options include:
- OEM Combustible Gas Detector
- OEM Natural Gas Detector
- OEM LPG Gas Alarm
- ODM Product Support
- Private Label Gas Detector
- Customer Logo Printing
- Customized Product Labels
- Retail Packaging Design
- Multilingual User Manuals
- Barcode Customization
- Master Carton Customization
- EU / US / AU Plug Selection
This allows professional buyers to build a gas safety product that matches their own brand and target market.
For a detector designed to continuously monitor combustible gases, consistent manufacturing is essential.
Quality control procedures for the JKD-838 include:
- Incoming material inspection
- PCB inspection
- AC power supply testing
- Catalytic sensor installation
- Gas detection function testing
- Alarm function verification
- Audible alarm inspection
- Visual indicator inspection
- Functional testing
- Aging inspection
- Appearance inspection
- Final quality inspection
- Packaging inspection
These procedures help maintain consistent quality across repeat production orders.
| Specification | JKD-838 |
|---|---|
| Model | JKD-838 |
| Product Type | EN50194 Combustible Gas Detector |
| Detection Applications | Natural Gas / LPG |
| Detection Gas | CH4 |
| Sensor Type | Catalytic Sensor |
| Sampling Method | Natural Diffusion |
| Standard | EN50194-1:2009 |
| Certification | SGS |
| Power Supply | AC 100–240V |
| Frequency | 50Hz |
| Plug Options | EU / US / AU |
| Maximum Power Consumption | 5W |
| Alarm Concentration | >8.0%LEL (4000ppm) |
| Alarm Method | Sound & Light Alarm |
| Alarm Volume | ≥85dB at 1m |
| Operating Temperature | -10°C to +50°C |
| Relative Humidity | ≤95%, No Condensation |
| Atmospheric Pressure | 86kPa–106kPa |
| Sampling | Natural Diffusion |
| Application Environment | Indoor |
| Maximum Sensor Lifetime | 5 Years |
| Dimensions | 120 * 75 * 40mm |
| Weight | Approx. 200g |
| OEM Service | Supported |
| ODM Service | Supported |
| Private Label | Supported |
| Logo Customization | Supported |
| Packaging Customization | Supported |
For professional distributors, certification documentation is an important part of product evaluation.
Available documentation for the JKD-838 includes:
- SGS Certification
- EN50194-1:2009 Documentation
- CE Documentation
- Technical Datasheet
- Product Specification
- User Manual
It is a gas detection device designed according to the EN50194 standard for combustible gas detection in domestic environments. JKD-838 is manufactured according to EN50194-1:2009.
Yes. SGS certification is one of the primary selling points of JKD-838.
Yes. The specified detection gas is CH4, making the product suitable for relevant natural gas/methane detection applications.
Yes. JKD-838 supports both natural gas and LPG detection applications.
It uses a catalytic gas sensor with natural diffusion sampling.
No. JKD-838 is an AC powered gas detector operating from AC 100–240V, 50Hz.
EU, US and AU plugs are available.
The specified alarm concentration is >8.0%LEL (4000ppm).
The alarm volume is ≥85dB at 1 meter.
Yes. OEM, ODM and private label gas alarm services are supported, including logo, product labels, packaging, manuals and plug customization.
The JKD-838 EN50194 Combustible Gas Detector is built around the features professional distributors care about: recognized certification, clear technical specifications, reliable sensing technology and flexible international configuration.
With SGS certification, EN50194-1:2009, catalytic sensing, natural gas and LPG applications, AC 100–240V operation, ≥85dB warning and EU/US/AU plug options, the JKD-838 provides a strong solution for residential gas safety portfolios.
The page also naturally covers multiple purchasing and SEO terms, including combustible gas detector, gas leak detector, natural gas detector, methane detector, CH4 gas detector, LPG gas detector, LPG leak alarm, flammable gas detector, residential gas alarm, home gas sensor, plug-in gas detector, AC powered gas alarm, EN50194 gas detector, SGS certified gas detector, OEM gas detector, ODM gas alarm, private label gas detector, gas detector manufacturer and gas alarm factory.
