Wall Mounted Ceiling Mounted Battery Powered Gas Alarm 0.5W Natural Gas Alarms
| Place of Origin | China |
|---|---|
| Brand Name | Symank |
| Certification | CE/ROHS/UKCA |
| Model Number | JKD-829 |
| Certificates | Gas alarm EN50194 Certi.pdf |
| Minimum Order Quantity | 100pcs |
| Price | Negotiable |
| Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Delivery Time | 5 days |
| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 50K |
| Name | Battery Powered Gas Alarm | Detection Gas Types | Natural Gas, Methane, Propane, LPG |
|---|---|---|---|
| Self-Diagnosis Function | Yes | Weight | Approximately 200 Grams |
| Operating Temperature | -10°C To 50°C | Operating Humidity | ≤95% RH (non-condensing) |
| Response Time | ≤10 Seconds | Sensor Type | Semiconductor Sensor |
| Power Consumption | ≤0.5W | Alarm Sound Level | ≥85dB At 1 Meter |
| Installation Method | Wall-mounted Or Ceiling-mounted | Dimensions | 100mm X 100mm X 40mm |
| Alarm Indicator | LED Light And Buzzer | Power Supply | DC 3V Lithium Battery |
| Highlight | Wall Mounted Battery Powered Gas Alarm,Ceiling Mounted Battery Powered Gas Alarm,0.5W Natural Gas Alarms |
||
Most traditional residential natural gas detectors are plug-in devices. They need to be installed close to an electrical socket, which means the available power outlet can influence where the gas detector is placed.
The JKD-829 Battery Powered Natural Gas Detector offers a different solution.
Powered by 2 * CR17505 lithium batteries, the JKD-829 operates independently from the household AC supply. There is no permanent power cable and no AC outlet required, giving users greater flexibility when selecting an appropriate installation location according to the product instructions.
This is not simply a minor specification.
For distributors, retailers and home safety brands looking for something different from another conventional plug-in methane gas alarm, JKD-829 provides a clear product proposition:
The detector also features a 10%LEL alarm setting, 0–20%LEL detection range, ≤30-second response time, LED status indication, sound and light warning, automatic reset and a specified five-year sensor life.
If a buyer compares ten residential gas leak detectors, many of them may look very similar.
Most will claim reliable detection.
Most will provide an audible warning.
And many conventional household gas alarms will require mains power.
JKD-829 takes a different approach.
This gives the product a very easy-to-understand purchasing reason:
- No AC socket required
- No permanent power cable
- Lithium battery powered
- More flexible installation
- Compact residential design
- Low working current
- Dedicated natural gas application
For professional buyers, this creates a differentiated product category rather than another variation of an ordinary AC gas alarm.
The JKD-829 operates from:
using:
The battery-powered architecture eliminates the need for a direct AC connection during normal operation.
This is particularly valuable when the preferred detector location does not have a convenient electrical outlet.
Compared with an AC-powered detector, the JKD-829 offers:
| Feature | JKD-829 |
|---|---|
| AC Outlet Required | No |
| Permanent Power Cable | No |
| Power Source | Lithium Battery |
| Power Supply | DC 6.0V |
| Batteries | 2 * CR17505 |
| Installation Flexibility | High |
| Main Application | Natural Gas |
The battery system is therefore not hidden in the specifications—it is the central product advantage.
A battery-powered combustible gas detector requires efficient power management.
The JKD-829 has a specified:
and:
The low working current supports the detector's lithium battery architecture and distinguishes it technically from conventional mains-powered gas detection products.
For distributors, this is an important feature to highlight when presenting the JKD-829 as a battery operated gas detector.
Another important difference between JKD-829 and JKD-831 is the target gas.
This distinction should be clear in product selection and marketing.
JKD-829 is specifically positioned for customers requiring natural gas detection, allowing it to target search and purchasing terms such as:
- Natural Gas Detector
- Natural Gas Leak Detector
- Methane Detector
- Methane Gas Alarm
- CH4 Gas Detector
- Battery Powered Natural Gas Detector
- Battery Operated Gas Alarm
- Lithium Battery Gas Detector
- Residential Natural Gas Alarm
- Home Gas Leak Detector
This focused positioning helps customers select the appropriate model for their intended gas application.
Natural gas detectors must be installed according to the target gas characteristics and the manufacturer's instructions.
With a conventional plug-in product, the installer must also consider the location of the nearest power outlet.
That creates two separate requirements:
Where should the detector be installed?
and
Is there an electrical socket there?
A battery-powered methane detector reduces this conflict.
Because JKD-829 does not rely on an AC socket, the installation decision can focus more directly on the appropriate detector location according to the product instructions and applicable requirements.
This is one of the most practical reasons for choosing a battery-powered design.
The JKD-829 has an alarm setting value of:
LEL means Lower Explosive Limit, a commonly used reference when describing combustible gas concentrations.
The detector provides a specified measurement range of:
with a repeatability error of:
When the detected natural gas reaches the defined alarm condition, the JKD-829 activates its sound and light warning.
For professional buyers comparing natural gas leak alarms, these clearly defined performance specifications provide a useful technical basis for evaluation.
The specified response time of the JKD-829 is:
When the relevant gas concentration reaches the specified detection condition, the detector responds and activates the alarm system.
Combined with its continuous low-power monitoring, this provides a practical solution for residential natural gas safety.
An effective home gas detector needs to make an alarm condition obvious.
JKD-829 provides:
The alarm sound pressure reaches:
An LED indicator provides visual status information, while the audible warning alerts occupants when an alarm condition occurs.
The combination of audible and visual indication provides a simple warning method for household applications.
JKD-829 uses:
When the alarm condition has cleared and the detected gas concentration returns to the appropriate level, the detector can automatically return to its normal monitoring state.
This simplifies everyday operation and reduces the need for unnecessary manual intervention.
The specified sensor life is:
A clearly defined sensor lifetime is important for both distributors and end users.
For professional buyers, it helps with:
- Product lifecycle planning
- Replacement recommendations
- After-sales communication
- Product documentation
- Retail information
- Portfolio management
This gives the JKD-829 a defined long-term role within a residential gas safety product range.
JKD-829 measures:
and weighs approximately:
Its compact housing and battery-powered design make it suitable for residential environments without requiring a permanent mains cable running from the detector to a socket.
Potential applications include:
- Houses using natural gas
- Residential kitchens
- Apartments
- Rental properties
- Residential buildings
- Holiday homes
- Indoor natural gas applications
Installation must always follow the supplied instructions and applicable local requirements.
The clearest way to understand the JKD-829 is to compare its power architecture with a conventional plug-in product.
| Feature | JKD-829 Battery Model | Typical Plug-in Model |
|---|---|---|
| Power Source | Lithium Battery | AC Mains |
| AC Outlet Required | No | Yes |
| Permanent Cable | No | Yes |
| Installation Flexibility | Higher | Limited by Socket Location |
| Main Application | Natural Gas | Model Dependent |
| Alarm Setting | 10%LEL | Model Dependent |
| Detection Range | 0–20%LEL | Model Dependent |
| Response Time | ≤30s | Model Dependent |
| Alarm | Sound + Light | Model Dependent |
| Sensor Life | 5 Years | Model Dependent |
Neither design needs to be presented as universally superior.
The difference is that JKD-829 gives buyers another choice—a natural gas detector specifically designed for customers who do not want their installation determined by an AC outlet.
From a distributor's perspective, JKD-829 fills a different position from standard AC gas alarms.
Its purchasing case is straightforward:
Two CR17505 lithium batteries eliminate dependence on mains power.
This is the clearest consumer-facing advantage.
Easy product positioning for markets using pipeline natural gas.
A clearly specified technical alarm value.
Provides a defined response specification for professional product comparison.
Supports clear product lifecycle communication.
Practical for residential applications.
Together, these features create a battery-powered natural gas detector category that can sit alongside traditional AC models rather than directly duplicating them.
The JKD-829 can complement other residential safety products such as:
- Smoke Detectors
- Carbon Monoxide Detectors
- CO + Smoke Alarms
- Natural Gas Detectors
- LPG Detectors
- Plug-in Gas Alarms
This gives home safety brands an opportunity to offer customers a choice between AC powered gas detection and lithium battery gas detection.
For distributors already carrying conventional plug-in products, this can expand the range without simply adding another nearly identical model.
The JKD-829 is particularly relevant for:
- Home safety distributors
- Gas safety wholesalers
- Fire safety distributors
- Electrical wholesalers
- Gas appliance distributors
- DIY retailers
- Home improvement retailers
- Importers
- Security product distributors
- Private-label safety brands
The simple selling proposition—Battery Powered Natural Gas Detection Without an AC Outlet—is easy for these customers to communicate to retailers and end users.
JKD-829 can be supplied for OEM and private-label projects.
Customization support can include:
- OEM Natural Gas Detector
- OEM Methane Gas Alarm
- ODM Project Support
- Private Label Gas Detector
- Custom Logo Printing
- Product Label Customization
- Retail Packaging Customization
- Multilingual User Manuals
- Barcode Customization
- Master Carton Customization
This allows distributors to develop a differentiated battery powered gas alarm under their own brand.
Consistent production and functional inspection are essential for residential gas detection products.
JKD-829 quality control procedures include:
- Incoming material inspection
- PCB inspection
- Battery supply verification
- Working current testing
- Sensor installation
- Gas detection function testing
- Alarm setting verification
- Response function testing
- LED indicator inspection
- Sound alarm inspection
- Automatic reset verification
- Appearance inspection
- Final product inspection
- Packaging inspection
These procedures help maintain consistent quality across production batches.
| Specification | JKD-829 |
|---|---|
| Model | JKD-829 |
| Product Type | Battery Powered Natural Gas Detector |
| Main Detected Gas | Natural Gas |
| Main Application | Residential Natural Gas Detection |
| Power Supply | DC 6.0V |
| Battery Type | 2 * CR17505 Lithium Batteries |
| Power Consumption | ≤0.3W |
| Working Current | ≤150μA |
| Alarm Setting Value | 10%LEL |
| Detection Range | 0–20%LEL |
| Repeatability Error | 3%LEL |
| Response Time | ≤30 Seconds |
| Display Mode | LED Indicator Light |
| Alarm Method | Sound & Light Alarm |
| Alarm Sound Pressure | ≥80dB at 1m Ahead |
| Reset Method | Automatic Reset |
| Sensor Life | 5 Years |
| Operating Temperature | -10°C to +55°C |
| Relative Humidity | ≤95% RH, No Condensation |
| Atmospheric Pressure | 86kPa–106kPa |
| Product Dimensions | 96 * 96 * 34mm |
| Product Weight | Approx. 170g |
| Operating Environment | Indoor Residential Use |
| OEM Service | Supported |
| ODM Service | Supported |
| Private Label | Supported |
| Packaging Customization | Supported |
Technical documentation can be provided for professional product evaluation and sourcing.
- Product Technical Datasheet
- Product Specification
- User Manual
- Available Compliance Documentation
Its primary difference is the lithium battery power supply. JKD-829 operates using two CR17505 batteries and does not require a permanent AC outlet.
Yes. The power supply is DC 6.0V using 2 * CR17505 lithium batteries.
JKD-829 is the natural gas detection model in this battery-powered series.
JKD-829 is designed for natural gas, while JKD-831 is designed for LPG / propane (C3H8).
The specified alarm setting is 10%LEL.
The specified range is 0–20%LEL.
The specified response time is ≤30 seconds.
The alarm sound pressure is ≥80dB at 1 meter ahead.
The specified sensor life is 5 years.
Yes. OEM, ODM and private-label services can support logo, labels, packaging and user manual customization.