Wall Mounted Ceiling Mounted Battery Powered Gas Alarm 0.5W Natural Gas Alarms

Place of Origin China
Brand Name Symank
Certification CE/ROHS/UKCA
Model Number JKD-829
Certificates Gas alarm EN50194 Certi.pdf
Minimum Order Quantity 100pcs
Price Negotiable
Packaging Details Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm
Delivery Time 5 days
Payment Terms L/C,T/T,Western Union
Supply Ability 50K
Product Details
Name Battery Powered Gas Alarm Detection Gas Types Natural Gas, Methane, Propane, LPG
Self-Diagnosis Function Yes Weight Approximately 200 Grams
Operating Temperature -10°C To 50°C Operating Humidity ≤95% RH (non-condensing)
Response Time ≤10 Seconds Sensor Type Semiconductor Sensor
Power Consumption ≤0.5W Alarm Sound Level ≥85dB At 1 Meter
Installation Method Wall-mounted Or Ceiling-mounted Dimensions 100mm X 100mm X 40mm
Alarm Indicator LED Light And Buzzer Power Supply DC 3V Lithium Battery
Highlight

Wall Mounted Battery Powered Gas Alarm

,

Ceiling Mounted Battery Powered Gas Alarm

,

0.5W Natural Gas Alarms

Leave a Message
Product Description
Battery Powered Natural Gas Detector with Lithium Battery
Natural Gas Detection Without Depending on an AC Outlet

Most traditional residential natural gas detectors are plug-in devices. They need to be installed close to an electrical socket, which means the available power outlet can influence where the gas detector is placed.

The JKD-829 Battery Powered Natural Gas Detector offers a different solution.

Powered by 2 * CR17505 lithium batteries, the JKD-829 operates independently from the household AC supply. There is no permanent power cable and no AC outlet required, giving users greater flexibility when selecting an appropriate installation location according to the product instructions.

This is not simply a minor specification.

Battery operation is the main reason to choose JKD-829.

For distributors, retailers and home safety brands looking for something different from another conventional plug-in methane gas alarm, JKD-829 provides a clear product proposition:

Natural Gas Detection + Lithium Battery Power + Flexible Installation

The detector also features a 10%LEL alarm setting, 0–20%LEL detection range, ≤30-second response time, LED status indication, sound and light warning, automatic reset and a specified five-year sensor life.

What Makes JKD-829 Different?

If a buyer compares ten residential gas leak detectors, many of them may look very similar.

Most will claim reliable detection.

Most will provide an audible warning.

And many conventional household gas alarms will require mains power.

JKD-829 takes a different approach.

It removes the dependence on an electrical outlet.

This gives the product a very easy-to-understand purchasing reason:

  • No AC socket required
  • No permanent power cable
  • Lithium battery powered
  • More flexible installation
  • Compact residential design
  • Low working current
  • Dedicated natural gas application

For professional buyers, this creates a differentiated product category rather than another variation of an ordinary AC gas alarm.

Powered by 2 * CR17505 Lithium Batteries

The JKD-829 operates from:

DC 6.0V

using:

2 * CR17505 Lithium Batteries

The battery-powered architecture eliminates the need for a direct AC connection during normal operation.

This is particularly valuable when the preferred detector location does not have a convenient electrical outlet.

Compared with an AC-powered detector, the JKD-829 offers:

Feature JKD-829
AC Outlet Required No
Permanent Power Cable No
Power Source Lithium Battery
Power Supply DC 6.0V
Batteries 2 * CR17505
Installation Flexibility High
Main Application Natural Gas

The battery system is therefore not hidden in the specifications—it is the central product advantage.

Low Power Consumption Makes Battery Operation Possible

A battery-powered combustible gas detector requires efficient power management.

The JKD-829 has a specified:

Power Consumption: ≤0.3W

and:

Working Current: ≤150μA

The low working current supports the detector's lithium battery architecture and distinguishes it technically from conventional mains-powered gas detection products.

For distributors, this is an important feature to highlight when presenting the JKD-829 as a battery operated gas detector.

Dedicated Natural Gas Detection

Another important difference between JKD-829 and JKD-831 is the target gas.

JKD-829 = Natural Gas
JKD-831 = LPG / Propane

This distinction should be clear in product selection and marketing.

JKD-829 is specifically positioned for customers requiring natural gas detection, allowing it to target search and purchasing terms such as:

  • Natural Gas Detector
  • Natural Gas Leak Detector
  • Methane Detector
  • Methane Gas Alarm
  • CH4 Gas Detector
  • Battery Powered Natural Gas Detector
  • Battery Operated Gas Alarm
  • Lithium Battery Gas Detector
  • Residential Natural Gas Alarm
  • Home Gas Leak Detector

This focused positioning helps customers select the appropriate model for their intended gas application.

Why a Battery Powered Methane Detector Can Be More Convenient

Natural gas detectors must be installed according to the target gas characteristics and the manufacturer's instructions.

With a conventional plug-in product, the installer must also consider the location of the nearest power outlet.

That creates two separate requirements:

Where should the detector be installed?

and

Is there an electrical socket there?

A battery-powered methane detector reduces this conflict.

Because JKD-829 does not rely on an AC socket, the installation decision can focus more directly on the appropriate detector location according to the product instructions and applicable requirements.

This is one of the most practical reasons for choosing a battery-powered design.

10%LEL Alarm Setting

The JKD-829 has an alarm setting value of:

10%LEL

LEL means Lower Explosive Limit, a commonly used reference when describing combustible gas concentrations.

The detector provides a specified measurement range of:

0–20%LEL

with a repeatability error of:

3%LEL

When the detected natural gas reaches the defined alarm condition, the JKD-829 activates its sound and light warning.

For professional buyers comparing natural gas leak alarms, these clearly defined performance specifications provide a useful technical basis for evaluation.

≤30 Seconds Response Time

The specified response time of the JKD-829 is:

≤30 Seconds

When the relevant gas concentration reaches the specified detection condition, the detector responds and activates the alarm system.

Combined with its continuous low-power monitoring, this provides a practical solution for residential natural gas safety.

Sound and Light Warning

An effective home gas detector needs to make an alarm condition obvious.

JKD-829 provides:

Sound Alarm + Light Alarm

The alarm sound pressure reaches:

≥80dB at 1 Meter Ahead

An LED indicator provides visual status information, while the audible warning alerts occupants when an alarm condition occurs.

The combination of audible and visual indication provides a simple warning method for household applications.

Automatic Reset

JKD-829 uses:

Automatic Reset

When the alarm condition has cleared and the detected gas concentration returns to the appropriate level, the detector can automatically return to its normal monitoring state.

This simplifies everyday operation and reduces the need for unnecessary manual intervention.

Five-Year Sensor Life

The specified sensor life is:

5 Years

A clearly defined sensor lifetime is important for both distributors and end users.

For professional buyers, it helps with:

  • Product lifecycle planning
  • Replacement recommendations
  • After-sales communication
  • Product documentation
  • Retail information
  • Portfolio management

This gives the JKD-829 a defined long-term role within a residential gas safety product range.

Compact Design for Flexible Residential Installation

JKD-829 measures:

96 * 96 * 34mm

and weighs approximately:

170g

Its compact housing and battery-powered design make it suitable for residential environments without requiring a permanent mains cable running from the detector to a socket.

Potential applications include:

  • Houses using natural gas
  • Residential kitchens
  • Apartments
  • Rental properties
  • Residential buildings
  • Holiday homes
  • Indoor natural gas applications

Installation must always follow the supplied instructions and applicable local requirements.

JKD-829 vs Traditional Plug-in Natural Gas Detector

The clearest way to understand the JKD-829 is to compare its power architecture with a conventional plug-in product.

Feature JKD-829 Battery Model Typical Plug-in Model
Power Source Lithium Battery AC Mains
AC Outlet Required No Yes
Permanent Cable No Yes
Installation Flexibility Higher Limited by Socket Location
Main Application Natural Gas Model Dependent
Alarm Setting 10%LEL Model Dependent
Detection Range 0–20%LEL Model Dependent
Response Time ≤30s Model Dependent
Alarm Sound + Light Model Dependent
Sensor Life 5 Years Model Dependent

Neither design needs to be presented as universally superior.

The difference is that JKD-829 gives buyers another choice—a natural gas detector specifically designed for customers who do not want their installation determined by an AC outlet.

Why Distributors Should Consider JKD-829

From a distributor's perspective, JKD-829 fills a different position from standard AC gas alarms.

Its purchasing case is straightforward:

1. Lithium Battery Powered

Two CR17505 lithium batteries eliminate dependence on mains power.

2. No AC Outlet Required

This is the clearest consumer-facing advantage.

3. Dedicated Natural Gas Application

Easy product positioning for markets using pipeline natural gas.

4. 10%LEL Alarm Setting

A clearly specified technical alarm value.

5. ≤30-Second Response

Provides a defined response specification for professional product comparison.

6. Five-Year Sensor Life

Supports clear product lifecycle communication.

7. Compact 96 * 96 * 34mm Housing

Practical for residential applications.

Together, these features create a battery-powered natural gas detector category that can sit alongside traditional AC models rather than directly duplicating them.

A Strong Addition to a Home Safety Product Range

The JKD-829 can complement other residential safety products such as:

  • Smoke Detectors
  • Carbon Monoxide Detectors
  • CO + Smoke Alarms
  • Natural Gas Detectors
  • LPG Detectors
  • Plug-in Gas Alarms

This gives home safety brands an opportunity to offer customers a choice between AC powered gas detection and lithium battery gas detection.

For distributors already carrying conventional plug-in products, this can expand the range without simply adding another nearly identical model.

Ideal B2B Customers

The JKD-829 is particularly relevant for:

  • Home safety distributors
  • Gas safety wholesalers
  • Fire safety distributors
  • Electrical wholesalers
  • Gas appliance distributors
  • DIY retailers
  • Home improvement retailers
  • Importers
  • Security product distributors
  • Private-label safety brands

The simple selling proposition—Battery Powered Natural Gas Detection Without an AC Outlet—is easy for these customers to communicate to retailers and end users.

OEM, ODM & Private Label Natural Gas Detector

JKD-829 can be supplied for OEM and private-label projects.

Customization support can include:

  • OEM Natural Gas Detector
  • OEM Methane Gas Alarm
  • ODM Project Support
  • Private Label Gas Detector
  • Custom Logo Printing
  • Product Label Customization
  • Retail Packaging Customization
  • Multilingual User Manuals
  • Barcode Customization
  • Master Carton Customization

This allows distributors to develop a differentiated battery powered gas alarm under their own brand.

Manufacturing & Quality Control

Consistent production and functional inspection are essential for residential gas detection products.

JKD-829 quality control procedures include:

  • Incoming material inspection
  • PCB inspection
  • Battery supply verification
  • Working current testing
  • Sensor installation
  • Gas detection function testing
  • Alarm setting verification
  • Response function testing
  • LED indicator inspection
  • Sound alarm inspection
  • Automatic reset verification
  • Appearance inspection
  • Final product inspection
  • Packaging inspection

These procedures help maintain consistent quality across production batches.

Technical Specifications
Specification JKD-829
Model JKD-829
Product Type Battery Powered Natural Gas Detector
Main Detected Gas Natural Gas
Main Application Residential Natural Gas Detection
Power Supply DC 6.0V
Battery Type 2 * CR17505 Lithium Batteries
Power Consumption ≤0.3W
Working Current ≤150μA
Alarm Setting Value 10%LEL
Detection Range 0–20%LEL
Repeatability Error 3%LEL
Response Time ≤30 Seconds
Display Mode LED Indicator Light
Alarm Method Sound & Light Alarm
Alarm Sound Pressure ≥80dB at 1m Ahead
Reset Method Automatic Reset
Sensor Life 5 Years
Operating Temperature -10°C to +55°C
Relative Humidity ≤95% RH, No Condensation
Atmospheric Pressure 86kPa–106kPa
Product Dimensions 96 * 96 * 34mm
Product Weight Approx. 170g
Operating Environment Indoor Residential Use
OEM Service Supported
ODM Service Supported
Private Label Supported
Packaging Customization Supported
Technical Documentation

Technical documentation can be provided for professional product evaluation and sourcing.

Available Documents
  • Product Technical Datasheet
  • Product Specification
  • User Manual
  • Available Compliance Documentation
Document Downloads

ROHS certificate.pdf

CE-LVD certificate.pdf

EN 50194 certificate.pdf

CE-EMC certificate.pdf

Frequently Asked Questions
What makes JKD-829 different from a traditional natural gas detector?

Its primary difference is the lithium battery power supply. JKD-829 operates using two CR17505 batteries and does not require a permanent AC outlet.

Is JKD-829 battery powered?

Yes. The power supply is DC 6.0V using 2 * CR17505 lithium batteries.

What gas does JKD-829 detect?

JKD-829 is the natural gas detection model in this battery-powered series.

What is the difference between JKD-829 and JKD-831?

JKD-829 is designed for natural gas, while JKD-831 is designed for LPG / propane (C3H8).

What is the alarm setting?

The specified alarm setting is 10%LEL.

What is the detection range?

The specified range is 0–20%LEL.

How fast does the detector respond?

The specified response time is ≤30 seconds.

How loud is the warning?

The alarm sound pressure is ≥80dB at 1 meter ahead.

What is the sensor lifetime?

The specified sensor life is 5 years.

Can JKD-829 be customized for our own brand?

Yes. OEM, ODM and private-label services can support logo, labels, packaging and user manual customization.