Contact Person : Chung
Phone Number : 8618126273416
Whatsapp : +8618126273416

SGS Certified Smoke and Carbon Monoxide Alarm with EN14604 and EN50291 Standards

Place of Origin CN
Brand Name Symank
Certification CE/ROHS/SGS
Model Number JKD-513COM
Certificates CE EN50291 Report.pdf
Minimum Order Quantity 100pcs
Price Negotiable
Packaging Details Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm
Delivery Time 5 days
Payment Terms L/C,D/P,T/T
Supply Ability 50K/month
Product Details
Operating Voltage DC 3V Productname Fire Alarm Smoke Detector
Dimensions Approx. 5 Inches Diameter, 1.5 Inches Thickness Display Digital Display For CO Levels
Alarm Sound Level 85 DB At 10 Feet Sensor Life Up To 10 Years
Installation Type Wall Or Ceiling Mount Endoflifesignal Yes
Sensitivityrange 0.10 To 0.15 DB/m Testbutton Yes
Responsetime Within 5 Seconds Mobile App Support Yes
Detectiontype Smoke And Carbon Monoxide Sensor Optical Speed,Photoelectric/optical
Highlight

commercial smoke carbon monoxide detector

,

smoke detector with 30-month warranty

,

easy to maintain carbon monoxide detector

Leave a Message
Product Description
SGS Certified Smoke and Carbon Monoxide Alarm for European Residential Safety
For B2B Buyers Certification Is Part of the Product

When distributors source residential safety products for Europe, price and appearance are only part of the purchasing decision.

The documentation behind the product matters.

A smoke and carbon monoxide alarm combines two different safety functions, so professional buyers need to evaluate the technical basis of both.

The JKD-513COM is designed for this requirement.

Its smoke alarm function follows:

EN14604:2005/AC:2008

while its carbon monoxide alarm function follows:

EN50291-1:2018.

The model is also SGS certified and supported by RoHS, EMC and UKCA compliance.

This makes certification the central purchasing reason for this JKD-513COM product page.

For importers, wholesalers, retailers and private-label brands looking for an EN14604 and EN50291 smoke and CO alarm, JKD-513COM provides two sensing functions and two corresponding product standards within one 10-year platform.


EN14604 for the Smoke Alarm Function

JKD-513COM uses a photoelectric reflection smoke sensor with specified smoke alarm sensitivity of:

0.25dB/m

The smoke function follows:

EN14604:2005/AC:2008

For distributors selling residential smoke alarms in Europe, EN14604 documentation is an important part of product evaluation.

The product also provides an approximately:

10-minute smoke alarm silence function

adding practical functionality for everyday residential use.

Instead of sourcing a generic smoke sensor with unclear technical positioning, buyers can offer a photoelectric smoke alarm with EN14604 compliance as part of a combined safety product.


EN50291 for Carbon Monoxide Monitoring

The second function of JKD-513COM is carbon monoxide monitoring.

It uses a dedicated:

Electrochemical CO Sensor

The carbon monoxide alarm function conforms to:

EN50291-1:2018

Its specified CO response settings are:

CO Concentration Alarm Response
50ppm Within 60 to 90 minutes
100ppm Within 10 to 40 minutes
300ppm Within 3 minutes

These defined response values provide technical buyers with measurable performance information when evaluating an EN50291 carbon monoxide alarm.

The result is not simply a product labelled "CO and Smoke."

Each hazard has its own sensing technology and corresponding standard.


Two EN Standards in One Residential Alarm

This is where JKD-513COM becomes particularly useful for distributors.

The product combines:

EN14604 Smoke Alarm

and

EN50291 Carbon Monoxide Alarm

within one housing.

For buyers building a home safety range, this creates a clear product category between standalone alarms and more complex connected safety systems.

The customer receives a combination smoke and CO alarm, while the distributor can present the technical basis of each sensing function separately.

This makes JKD-513COM suitable for brands looking for a certified smoke and carbon monoxide alarm for European residential applications.


SGS Certification for Supplier Evaluation

JKD-513COM is supported by SGS certification.

For B2B customers, third-party certification can be particularly useful during:

  • Product sourcing
  • Supplier qualification
  • Technical review
  • Compliance assessment
  • Retail product approval
  • Private-label development
  • Purchasing department evaluation

This is why certification should not be treated as a small icon at the bottom of a product page.

For professional buyers, it can be one of the reasons to shortlist a supplier.


RoHS EMC and UKCA Support

Beyond EN14604 and EN50291, JKD-513COM also has:

RoHS

EMC

UKCA

documentation.

This broader compliance package is useful for distributors selling through different European and UK channels.

For an OEM customer, having multiple relevant documents available from the same supplier can also make internal product evaluation more efficient.


10 Year Product Life

JKD-513COM has a specified:

10 Year Product Life After Manufacture

This gives the model a long-term positioning compared with basic short-life alarms.

It allows distributors to market the product using relevant long-tail search terms such as:

10 year smoke and carbon monoxide alarm

10 year CO smoke alarm for home

and:

long life residential smoke and CO sensor

without relying on vague terms such as "premium" or "high quality."


Replaceable AA Battery Power

JKD-513COM operates with:

3 x 1.5V AA Alkaline Batteries

This gives users a familiar, replaceable power source during the detector's product lifecycle.

The average standby current is:

Less than 50μA

while the average alarm current is:

Less than 70mA.

This battery architecture also gives distributors an alternative to sealed-lithium models for customers who prefer replaceable AA batteries.


Sound and Visual Warning

JKD-513COM is classified as:

Type B to provide a visual and audible alarm only

The specified audible warning reaches:

At Least 85dB at 3 Meters

The combination of visual and audible indication provides a clear warning when the applicable smoke or carbon monoxide alarm condition occurs.


Residential Installation

JKD-513COM supports:

Ceiling or Wall Installation

with a specified detection range of:

Maximum 40m² Within a Room

The housing measures approximately:

Φ105 x 39mm

and weighs:

180 plus or minus 10g net.

Operating conditions are specified from -10°C to +50°C with relative humidity below 95 percent RH non-condensing.


Why This Model Makes Sense for European Distributors

The main reason to source JKD-513COM is not one isolated feature.

It is the way its compliance structure matches its two safety functions:

Function Technology Standard
Smoke Alarm Photoelectric Reflection Sensor EN14604:2005/AC:2008
CO Alarm Electrochemical Sensor EN50291-1:2018

Add SGS certification, RoHS, EMC, UKCA and a 10-year product life, and the model becomes particularly relevant for distributors building a documented residential safety portfolio.

OEM, ODM and private-label cooperation can also support custom logos, packaging, labels and multilingual manuals.

Technical Specifications
Technical Item Specification
Model JKD-513COM
Product Type Combination Smoke and Carbon Monoxide Alarm
Product Life 10 Years After Manufacture
Power Supply 3 x 1.5V AA Alkaline Batteries
Type of Apparatus Type B Visual and Audible Alarm Only
Smoke Sensor Photoelectric Reflection
Smoke Alarm Sensitivity 0.25dB/m
Smoke Silence Function About 10 Minutes
Smoke Standard EN14604:2005/AC:2008
CO Sensor Electrochemical
CO Standard EN50291-1:2018
50ppm CO Response 60 to 90 Minutes
100ppm CO Response 10 to 40 Minutes
300ppm CO Response Within 3 Minutes
Standby Current Less Than 50μA Average
Alarm Current Less Than 70mA Average
Alarm Method Visual and Audible Alarm
Alarm Sound Pressure At Least 85dB at 3m
Operating Temperature -10°C to +50°C
Operating Humidity Less Than 95 Percent RH Non Condensing
Storage and Transport Temperature -10°C to +50°C
Storage and Transport Humidity Less Than 95 Percent RH Non Condensing
Installation Location Ceiling or Wall
Detection Range Maximum 40m² Within a Room
Dimensions Approx. Φ105 x 39mm
Weight 180 Plus or Minus 10g Net
Certification SGS
Smoke Compliance EN14604:2005/AC:2008
CO Compliance EN50291-1:2018
Additional Compliance RoHS EMC UKCA
OEM Supported
ODM Supported
Private Label Supported
Certifications and Technical Documents

For professional buyers, the JKD-513COM documentation package includes:

SGS Certification

EN14604:2005/AC:2008

EN50291-1:2018

RoHS

EMC

UKCA

Product specifications, technical datasheets, user manuals and relevant certification documents can be provided for customer evaluation.


CE EN50291 Report.pdf


CE EN14604(CPR) Report.pdf

Frequently Asked Questions
Is JKD-513COM an EN14604 smoke alarm?

Yes. Its smoke alarm function follows EN14604:2005/AC:2008.

Does the carbon monoxide sensor comply with EN50291?

Yes. The CO function conforms to EN50291-1:2018.

Is JKD-513COM SGS certified?

Yes. SGS certification is available for this model.

What sensors are used?

The product combines a photoelectric smoke sensor and an electrochemical CO sensor.

How long is the product life?

The specified product life is 10 years after manufacture.

What batteries does it use?

It operates with 3 x 1.5V AA alkaline batteries.

What is the alarm sound level?

The specified sound pressure is at least 85dB at 3 meters.

What area can one alarm cover?

The specified detection range is maximum 40m² within a room.

Is OEM private label production supported?

Yes. OEM, ODM and private-label projects are supported.