Low-Power Battery Gas Sensor for Natural Gas Detection
| Place of Origin | China |
|---|---|
| Brand Name | Symank |
| Certification | CE/ROHS/UKCA |
| Model Number | JKD-829 |
| Certificates | Gas alarm EN50194 Certi.pdf |
| Minimum Order Quantity | 100pcs |
| Price | Negotiable |
| Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Delivery Time | 5 days |
| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 50K/Month |
| Name | Gas Leak Alarm | Usage | Gas Detection In Fire Alarm System |
|---|---|---|---|
| Mounting Type | Wall Mount | Response Time | Within 30 Seconds |
| Temperature Range | -10°C To 50°C (14°F To 122°F) | Certifications | CE Listed, EN50194 Compliant |
| Operating Voltage | 6V DC | Material | ABS Plastic |
| Power Source | Battery Operated | Sensitivity | Meets EN50194 Standards |
| Test Button | Yes, For Manual Testing | Environmental Temperature | -10℃ ~ +55℃ |
| Led Indicator | Power And Alarm Status | ||
| Highlight | OEM Gas Leak Alarm,EN50194 Battery Operated Gas Detector,Battery Operated Gas Detector Professional |
||
A battery-powered natural gas detector sounds simple.
Remove the AC cable.
Install batteries.
Turn on the detector.
But from a product engineering perspective, the real question is more important:
The answer depends heavily on power management.
The JKD-829 Low-Power Natural Gas Sensor is designed around a working current of:
with overall power consumption of:
and a power supply consisting of:
This low-power architecture is the central selling point of this JKD-829 page.
For distributors looking for something different from another AC-powered gas leak alarm, JKD-829 combines lithium battery operation with low working current to create a dedicated residential natural gas detection solution.
A gas detector is not a product that only needs power for a few seconds when the user presses a button.
Its purpose is to monitor the relevant environment during normal operation.
That makes power consumption particularly important for a battery-operated model.
JKD-829 provides:
≤150μA Working Current
≤0.3W Power Consumption
2 * CR17505 Lithium Batteries
This combination is what makes its battery-powered architecture commercially interesting.
The buying reason is therefore not simply:
“It has batteries."
It is:
That is a much stronger B2B product position.
The specified working current of JKD-829 is:
For a lithium battery gas detection product, this is an important technical parameter.
Low working current helps reduce the electrical load during normal detector operation and supports the product's battery-powered architecture.
This gives professional buyers a measurable specification when comparing different battery gas detectors, rather than relying only on broad marketing claims such as "low consumption."
The specified overall power consumption is:
Combined with the ≤150μA working current, this reinforces the low-power positioning of JKD-829.
For distributors, these specifications can be useful when presenting the product to technically oriented customers looking for:
- Low Power Gas Detector
- Battery Gas Sensor
- Lithium Battery Gas Alarm
- Natural Gas Sensor
- Low Current Methane Detector
- Battery Operated Gas Detector
This provides a different product story from conventional mains-powered residential gas alarms.
JKD-829 operates from:
using:
The battery architecture means the detector does not require a permanent AC connection during normal operation.
This brings a second practical benefit to the low-power design:
However, unlike the previous JKD-829 page where installation flexibility was the main selling point, here battery power supports the central story:
JKD-829 is the natural gas version of this battery-powered detector platform.
The model should therefore be clearly differentiated from JKD-831:
| Model | Main Gas Application |
|---|---|
| JKD-829 | Natural Gas |
| JKD-831 | LPG / Propane |
This gives JKD-829 a clear market identity rather than positioning it as a generic multi-gas product.
Relevant buyer terminology includes:
- Natural Gas Detector
- Natural Gas Sensor
- Methane Detector
- Methane Gas Sensor
- CH4 Detector
- Natural Gas Leak Alarm
- Residential Gas Detector
- Home Gas Sensor
- Battery Gas Detector
- Combustible Gas Detector
Using these related terms also broadens the SEO coverage beyond repeatedly using only gas alarm.
JKD-829 has a specified alarm setting of:
LEL refers to the Lower Explosive Limit, a standard reference used when describing combustible gas concentration.
The detector's specified measurement range is:
with:
These defined technical parameters allow B2B buyers to evaluate the product using measurable specifications rather than general claims.
The specified range of JKD-829 is:
This gives the product a defined operating range for its gas detection function.
For technical buyers comparing several natural gas sensors, clearly stated information such as alarm setting, detection range, response time and repeatability can be more useful than a long list of generic marketing features.
JKD-829 provides all four:
Alarm Setting: 10%LEL
Range: 0–20%LEL
Repeatability Error: 3%LEL
Response Time: ≤30 seconds
The specified response time is:
When the relevant gas concentration reaches the specified detection condition, the JKD-829 responds and activates its warning system.
This provides distributors with another measurable performance parameter for technical comparison.
Rather than simply advertising "fast response," the product provides a specific value:
When an alarm condition occurs, JKD-829 provides:
The specified alarm sound pressure is:
The combination of sound and light warning gives occupants a clear indication of an alarm event.
The LED also provides a straightforward visual display method for the detector.
JKD-829 uses:
When the gas concentration returns to the appropriate condition following an alarm event, the detector can return automatically to its normal monitoring state.
This makes operation simpler for residential users and reduces unnecessary manual interaction.
The specified sensor lifetime is:
For professional distributors, a defined sensor life helps with:
- Product lifecycle planning
- Replacement recommendations
- User documentation
- Retail information
- Customer communication
- After-sales planning
Combined with the low-power battery architecture, the five-year sensor specification gives JKD-829 a clear long-term residential product position.
The value of low power consumption becomes clearer when looking at the purpose of the device.
A home natural gas detector is not intended to operate only when the user actively checks it.
Its value comes from being available for gas monitoring during normal use.
For an AC detector, the electrical supply comes directly from the mains.
For a battery-operated detector, power efficiency becomes much more important.
This is why:
is not just another number in the specification table.
It supports the entire product concept.
These two architectures solve the power requirement differently.
| Feature | JKD-829 | AC Gas Detector |
|---|---|---|
| Main Power | Lithium Battery | AC Mains |
| Battery Type | 2 * CR17505 | — |
| Working Current | ≤150μA | Model Dependent |
| Power Consumption | ≤0.3W | Model Dependent |
| Permanent AC Connection | Not Required | Required |
| Power Cable | Not Required | Usually Required |
| Main Product Position | Low-Power Battery Detection | Continuous Mains Power |
The purpose is not to claim that one architecture is universally superior.
Instead, JKD-829 gives distributors a technically differentiated battery-powered option.
A distributor may already carry conventional plug-in gas detectors.
Adding JKD-829 does not simply duplicate the same product.
It creates another category:
A home safety product range could therefore offer:
Plug-in Natural Gas Detector
for customers preferring mains power.
and
JKD-829 Battery Natural Gas Detector
for customers preferring a low-power lithium battery solution.
This gives retailers and end users more choice.
JKD-829 measures:
with an approximate weight of:
The compact housing integrates the battery system, gas detection components, LED indication and audible warning into one residential device.
Its size also supports straightforward retail packaging and transportation for distributors.
JKD-829 is designed to operate within the following specified conditions:
| Parameter | Specification |
|---|---|
| Operating Temperature | -10°C to +55°C |
| Relative Humidity | ≤95% RH, No Condensation |
| Atmospheric Pressure | 86kPa–106kPa |
This provides a defined operating environment for residential natural gas detection applications.
Potential applications include:
- Residential kitchens
- Apartments
- Houses
- Rental properties
- Residential buildings
- Holiday homes
- Indoor natural gas environments
Installation should follow the supplied product instructions and applicable requirements.
The buying logic is straightforward.
Supports the low-power battery architecture.
Provides another measurable low-consumption specification.
No permanent AC connection required.
Clear positioning for residential natural gas markets.
Defined combustible gas warning specification.
Clear technical detection range.
Measurable response performance.
Defined product lifecycle.
Together, these features make JKD-829 particularly suitable for buyers seeking a low-power residential natural gas sensor rather than another conventional plug-in alarm.
JKD-829 can be suitable for:
- Gas safety distributors
- Home safety brands
- Fire safety wholesalers
- Electrical wholesalers
- Gas appliance distributors
- Home improvement retailers
- DIY retailers
- Importers
- Security product distributors
- Private-label brands
For distributors already carrying smoke and CO detectors, JKD-829 can also extend the range into battery-powered combustible gas detection.
JKD-829 supports professional OEM and private-label projects.
Customization can include:
- OEM Natural Gas Detector
- OEM Methane Detector
- OEM Gas Sensor
- ODM Project Support
- Private Label Gas Detector
- Custom Logo
- Product Label Customization
- Retail Packaging
- Multilingual User Manual
- Barcode Customization
- Master Carton Customization
This allows professional customers to integrate JKD-829 into their own residential safety range.
For a low-power battery product, both gas detection performance and electrical consumption are important production considerations.
Quality control procedures can include:
- Incoming material inspection
- PCB inspection
- Battery supply verification
- Working current testing
- Power consumption inspection
- Sensor installation
- Gas detection function testing
- Alarm setting verification
- Response function testing
- LED indicator inspection
- Audible warning inspection
- Automatic reset testing
- Appearance inspection
- Final product inspection
- Packaging inspection
These procedures help support consistent production across repeat orders.
| Specification | JKD-829 |
|---|---|
| Model | JKD-829 |
| Product Type | Low-Power Battery Natural Gas Detector |
| Main Application | Natural Gas Detection |
| Power Supply | DC 6.0V |
| Battery | 2 * CR17505 |
| Power Consumption | ≤0.3W |
| Working Current | ≤150μA |
| Alarm Setting Value | 10%LEL |
| Detection Range | 0–20%LEL |
| Repeatability Error | 3%LEL |
| Response Time | ≤30 Seconds |
| Display Mode | LED Indicator Light |
| Alarm Method | Sound & Light |
| Alarm Sound Pressure | ≥80dB at 1m Ahead |
| Reset Method | Automatic Reset |
| Sensor Life | 5 Years |
| Operating Temperature | -10°C to +55°C |
| Relative Humidity | ≤95% RH, No Condensation |
| Atmospheric Pressure | 86kPa–106kPa |
| Dimensions | 96 * 96 * 34mm |
| Weight | Approx. 170g |
| OEM | Supported |
| ODM | Supported |
| Private Label | Supported |
| Packaging Customization | Supported |
Available product documentation can include:
- Product Technical Datasheet
- Product Specification
- User Manual
- Available Compliance Documentation
This version is positioned around its low-power battery architecture, with ≤150μA working current and ≤0.3W power consumption.
JKD-829 operates from DC 6.0V using 2 * CR17505 lithium batteries.
The specified working current is ≤150μA.
The specified power consumption is ≤0.3W.
JKD-829 is the natural gas model in this battery-powered product series.
The specified alarm setting value is 10%LEL.
The specified detection range is 0–20%LEL.
The specified response time is ≤30 seconds.
The specified alarm sound pressure is ≥80dB at 1 meter ahead.
The specified sensor life is 5 years.
Yes. OEM, ODM and private-label customization are supported.