Low Power Plug in Gas Detector for 24/7 Home Monitoring

Place of Origin China
Brand Name Symank
Certification CE/ROHS/UKCA/SGS
Model Number JKD-839
Certificates Gas alarm EN50194 Certi.pdf
Minimum Order Quantity 100pcs
Price Negotiable
Packaging Details Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm
Delivery Time 5 days
Payment Terms L/C,T/T,Western Union
Supply Ability 50K/Month
Product Details
Name Gas Leak Alarm Dimensions 120mm X 70mm X 40mm
Response Time Less Than 10 Seconds Warranty 2 Year
Alarm Indicator LED And Audible Alarm Weight 200 Grams
Sensor Type Semiconductor Sensor Alarm Sound Level 85 DB At 1 Meter
Reset Method Manual Reset Button Detection Gas Types Natural Gas, Methane, Propane, Butane
Power Supply AC 90-220V Or DC 9V Battery Operating Humidity 10% To 90% RH Non-condensing
Installation Method Wall-mounted Or Tabletop Operating Temperature -10°C To 50°C
Highlight

EN50194 Approval Gas Leak Alarm

,

SGS Approval Gas Leak Alarm

,

Professional House Gas Detector

Leave a Message
Product Description
Gas Does Not Follow a Schedule — Your Detector Should Not Either

A residential gas leak can occur at any time.

During cooking.

During the night.

When a gas appliance is operating.

Or simply when nobody is actively thinking about gas safety.

That is why the JKD-839 Plug-in Gas Detector is designed around a simple principle:

Continuous Gas Monitoring

JKD-839 operates directly from:

AC 100–240V, 50Hz

with maximum power consumption of only:

5W

Once properly installed and powered, the detector can continuously monitor the relevant indoor environment during normal operation without requiring users to routinely replace batteries.

For buyers comparing a plug-in natural gas detector with battery-powered alternatives, this is the main reason to choose JKD-839:

Plug It In. Keep It Powered. Keep Monitoring.
What Makes JKD-839 Different?

Not every customer wants the same power solution.

Battery-powered gas detectors provide installation flexibility, but they depend on batteries as their operating power source.

JKD-839 takes the opposite approach.

It is designed for customers who prefer:

  • Continuous mains power
  • No routine battery replacement
  • Permanent residential monitoring
  • Simple plug-in operation
  • Low maximum power consumption
  • Wide AC 100–240V input

This gives distributors two clearly differentiated product categories.

Battery Models

Focused on installation flexibility.

JKD-839 Plug-in Model

Focused on continuous mains-powered monitoring.

Neither approach needs to be presented as universally better.

They serve different customer requirements.

Maximum Power Consumption of Only 5W

A product designed for continuous operation should not require excessive power.

JKD-839 has a specified maximum power consumption of:

5W

This makes low power consumption an important supporting feature of its continuous-monitoring design.

For a residential detector expected to remain powered during normal use, this provides a practical balance between:

Continuous Monitoring

and

Low Power Consumption

This is especially relevant for distributors positioning JKD-839 as a permanent home gas monitoring device rather than a product that users only activate occasionally.

AC 100–240V Wide Voltage Input

The power supply specification is:

AC 100–240V, 50Hz

The wide voltage range gives professional buyers greater flexibility for international markets.

Available plug configurations include:

  • EU Plug
  • US Plug
  • AU Plug

For international distributors, this means the same core gas detection device can be adapted to different plug configurations while maintaining its AC-powered architecture.

Why Choose a Plug-in Gas Detector?

For some residential applications, the strongest advantage of AC power is simplicity.

The user does not need to think about replacing the operating batteries as part of normal power supply management.

Once the detector is properly installed and connected to power, it remains available for continuous monitoring.

This makes JKD-839 particularly attractive for:

  • Permanent residential installation
  • Apartments
  • Houses
  • Rental properties
  • Residential kitchens
  • Holiday homes
  • Property management applications
  • Long-term indoor gas monitoring

For distributors, the consumer-facing message is easy to understand:

No Routine Battery Replacement — Continuous AC-Powered Gas Monitoring
Natural Gas Monitoring

The JKD-839 supports residential natural gas applications.

Its specified detection gas is:

CH4

Methane is the primary component of natural gas, making JKD-839 suitable for relevant methane detection applications.

The product can therefore be positioned using multiple search and purchasing terms:

  • Natural Gas Detector
  • Methane Detector
  • CH4 Gas Detector
  • Natural Gas Leak Detector
  • Methane Gas Sensor
  • Natural Gas Alarm
  • Residential Gas Detector
  • Home Gas Sensor

This terminology variation is useful because professional buyers often use different phrases when sourcing the same product category.

LPG Detection Applications

JKD-839 can also support LPG detection applications.

This expands its potential market beyond homes using pipeline natural gas.

For LPG-oriented markets, relevant terms include:

  • LPG Gas Detector
  • LPG Leak Detector
  • LPG Gas Alarm
  • LPG Gas Sensor
  • Home LPG Detector
  • Residential LPG Alarm
  • Combustible Gas Detector
  • Flammable Gas Detector

This allows distributors to position the JKD-839 for different residential gas applications while retaining the same plug-in product platform.

Catalytic Sensor for Combustible Gas Detection

The JKD-839 uses a:

Catalytic Sensor

with:

Natural Diffusion Sampling

Surrounding air naturally reaches the sensing area, allowing the sensor to monitor the relevant combustible gas during normal operation.

The maximum specified sensor lifetime is:

5 Years

This creates a complete continuous-monitoring architecture:

AC Power

Continuous Operation

Natural Diffusion

Catalytic Gas Sensing

Alarm When the Specified Condition Is Reached

The user does not need to manually sample the surrounding air.

>8.0%LEL Alarm Concentration

The specified alarm concentration is:

>8.0%LEL (4000ppm)

LEL refers to the Lower Explosive Limit, commonly used when describing combustible gas concentrations.

Once the specified alarm condition is reached, the detector activates:

Sound + Light Warning

For B2B buyers, the defined alarm concentration provides a measurable technical specification for product comparison.

≥85dB Audible Warning

JKD-839 provides a specified alarm volume of:

≥85dB at 1 Meter

The audible warning is combined with light indication.

The purpose is straightforward: when the detector enters an alarm condition, occupants should receive a clear warning.

The combination of continuous monitoring and a strong audible warning is particularly relevant for a product intended to remain powered around the clock.

SGS Certified Gas Detection

JKD-839 is supported by:

SGS Certification

For professional buyers, third-party certification provides additional technical support when evaluating a residential gas safety product.

This can be important for:

  • Distributor product evaluation
  • Supplier qualification
  • Procurement review
  • Technical documentation
  • Customer inquiries
  • Product portfolio development

It also helps distinguish JKD-839 from generic plug-in gas alarms with unclear testing documentation.

EN50194-1:2009

The JKD-839 is manufactured according to:

EN50194-1:2009

For buyers targeting European residential markets, the combination becomes particularly attractive:

Continuous AC Power + Max. 5W + EN50194 + SGS

This gives the product both a practical consumer benefit and a professional B2B purchasing foundation.

Plug-in vs Battery Powered Gas Detector

The two power architectures serve different priorities.

Feature JKD-839 Plug-in Model Battery Gas Detector
Main Power Source AC Mains Battery
Continuous Mains Power Yes No
Routine Operating Battery Replacement No Depends on Battery Design
Maximum Power Consumption 5W Model Dependent
Installation Requires Suitable Outlet More Flexible
Best Selling Point Continuous Powered Monitoring Installation Freedom
Typical Buyer Permanent Installation Cordless Installation Requirement

This gives distributors an opportunity to offer customers a choice instead of trying to claim one power solution is ideal for every application.

Why Distributors Should Carry a Plug-in Model

A complete residential gas safety range should address different customer preferences.

Some buyers prioritize cordless installation.

Others prefer a detector that remains continuously connected to household power.

JKD-839 fills the second requirement.

For distributors already selling battery-operated models, adding a plug-in gas leak detector can broaden the product range and allow the customer to select the power architecture that best matches the intended installation.

A Good Fit for Rental and Property Management Applications

Continuous plug-in monitoring can also make JKD-839 attractive for residential property applications where the detector is intended to remain installed in a fixed location.

Potential channels include:

  • Residential property suppliers
  • Property management companies
  • Rental property distributors
  • Home safety retailers
  • Gas appliance distributors
  • Electrical wholesalers
  • Fire safety distributors
  • DIY retailers

For these buyers, a fixed AC-powered gas sensor can provide a straightforward long-term installation solution.

Designed for Indoor Residential Environments

JKD-839 operates within the following specified environmental conditions:

Parameter Specification
Operating Temperature -10°C to +50°C
Relative Humidity ≤95%, Non-condensing
Atmospheric Pressure 86kPa–106kPa
Application Indoor Use

The detector can be used in relevant residential environments using natural gas or LPG.

Actual installation position should follow the product manual and requirements appropriate to the target gas.

Compact 120 * 75 * 40mm Design

Continuous AC-powered operation does not require an oversized housing.

JKD-839 measures approximately:

120 * 75 * 40mm

with an approximate weight of:

200g

The compact enclosure integrates the power architecture, catalytic sensor and alarm functions into a residential format suitable for indoor installation.

Who Should Buy JKD-839?

JKD-839 is particularly suitable for professional customers looking for a permanently powered residential gas detection solution.

Typical buyers include:

  • Gas safety distributors
  • Home safety brands
  • Fire safety wholesalers
  • Electrical wholesalers
  • Property safety suppliers
  • Gas appliance distributors
  • Home improvement retailers
  • DIY chains
  • Importers
  • Private-label brands

For these customers, the central purchasing reason remains simple:

Reliable continuous monitoring without routine operating-battery replacement.
OEM & ODM Plug-in Gas Detector

JKD-839 can support professional OEM and private-label projects.

Customization options can include:

  • OEM Gas Detector
  • OEM Natural Gas Detector
  • OEM LPG Detector
  • OEM Methane Gas Alarm
  • ODM Project Support
  • Private Label Gas Sensor
  • Custom Logo
  • Product Label Customization
  • Retail Packaging
  • Multilingual User Manual
  • Barcode Customization
  • Master Carton Customization
  • EU / US / AU Plug Selection

This allows distributors to build their own branded plug-in gas safety range.

Manufacturing & Quality Control

Because JKD-839 is intended for continuous powered operation, both gas detection and electrical functions are important during production inspection.

Quality control procedures include:

  • Incoming material inspection
  • PCB inspection
  • AC input verification
  • Power consumption inspection
  • Catalytic sensor installation
  • Gas detection function testing
  • Alarm concentration verification
  • Sound alarm testing
  • Light indication testing
  • Functional testing
  • Aging inspection
  • Appearance inspection
  • Final product inspection
  • Packaging inspection

These procedures help maintain consistent production quality across repeat orders.

Technical Specifications
Specification JKD-839
Model JKD-839
Product Type Low-Power Plug-in Gas Detector
Detection Applications Natural Gas / LPG
Detection Gas CH4
Sensor Type Catalytic Sensor
Sampling Method Natural Diffusion
Standard EN50194-1:2009
Certification SGS
Supply Voltage AC 100–240V
Frequency 50Hz
Maximum Power Consumption 5W
Plug Options EU / US / AU
Alarm Concentration >8.0%LEL (4000ppm)
Alarm Method Sound & Light
Alarm Volume ≥85dB at 1m
Operating Temperature -10°C to +50°C
Relative Humidity ≤95%, No Condensation
Atmospheric Pressure 86kPa–106kPa
Operating Environment Indoor
Maximum Sensor Lifetime 5 Years
Dimensions Approx. 120 * 75 * 40mm
Weight Approx. 200g
OEM Supported
ODM Supported
Private Label Supported
Plug Customization EU / US / AU
Certifications & Technical Documentation

Available technical documentation for professional buyers includes:

  • SGS Certification
  • EN50194-1:2009 Documentation
  • Product Technical Datasheet
  • Product Specification
  • User Manual
  • Available Compliance Documentation
Certificate & Document Downloads

Gas alarm EN50194 Certi.pdf


Gas Alarm UKCA Certi.pdf


Gas Alarm ROHS Certi.pdf

Frequently Asked Questions
What is the main advantage of JKD-839?

This version is positioned around continuous AC-powered monitoring. It operates from AC 100–240V with maximum power consumption of 5W, eliminating routine operating-battery replacement.

How much power does JKD-839 consume?

The specified maximum power consumption is 5W.

Is JKD-839 battery powered?

No. JKD-839 is a plug-in gas detector using AC 100–240V, 50Hz.

Which plugs are available?

EU, US and AU plug versions are available.

Can JKD-839 detect natural gas?

Yes. Its specified detection gas is CH4, supporting relevant natural gas/methane applications.

Can it be used for LPG?

Yes. The JKD-839 platform supports natural gas and LPG applications.

What sensor does it use?

JKD-839 uses a catalytic sensor with natural diffusion sampling.

What is the alarm concentration?

The specified alarm concentration is >8.0%LEL (4000ppm).

What is the alarm volume?

The specified audible warning is ≥85dB at 1 meter.

What is the sensor lifetime?

The maximum specified sensor lifetime is 5 years.

Is OEM available?

Yes. OEM, ODM and private-label customization are supported.