85dB Smoke and Carbon Monoxide Alarm with Visual and Audible Warning
| Place of Origin | China |
|---|---|
| Brand Name | Symank |
| Certification | SGS/CE/ROHS/UKCA |
| Model Number | JKD-514COM |
| Minimum Order Quantity | 100pcs |
| Price | Negotiable |
| Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Delivery Time | 5 days |
| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 50K/Month |
| Name | Smoke And CO Alarms | Certifications | CE/ROHS Certified |
|---|---|---|---|
| Power Source | Battery-operated | Silence/Hush Feature | Yes |
| Installation Type | Wall Or Ceiling Mount | Operating Temperature Range | -10°C To 50°C (14°F To 122°F) |
| Battery Life | Up To 10 Years (depending On Model) | End-Of-Life Warning | Yes |
| Test Button | Yes | Display | Digital Display For CO Levels |
| Dimensions | Approximately 105*40MM | Detection Type | Smoke And Carbon Monoxide |
| Sensor Type | Electrochemical (for CO) And Photoelectric / Ionization (for Smoke) | Alarm Sound Level | 85 DB At 10 Feet |
| Highlight | SGS Approved Smoke And CO Alarms,85dB Home Carbon Monoxide Detectors,Home Carbon Monoxide Detectors OEM |
||
The purpose of a home safety alarm is not simply to sense a hazard.
Once smoke or carbon monoxide reaches an applicable alarm condition, the product must communicate that danger clearly to people inside the home.
This is the core focus of the JKD-514COM smoke and carbon monoxide alarm.
The product combines visual indication with a specified audible alarm level of:
JKD-514COM is classified as a Type B apparatus designed to provide visual and audible alarm only.
For distributors and residential safety brands, this creates a clear purchasing proposition: one combined alarm monitors both smoke and carbon monoxide and provides a strong audible warning together with visual indication when an applicable alarm condition occurs.
The specified alarm sound pressure of JKD-514COM is:
≥85dB at 3m
This is an important technical parameter for a residential smoke and CO alarm, because sensing a hazard is only one part of the safety function.
The alarm must also alert occupants.
Rather than describing the product with vague phrases such as "loud alarm," JKD-514COM provides a measurable sound-pressure specification.
For B2B buyers comparing residential safety products, this provides a concrete parameter that can be included in catalogs, technical datasheets and retail product descriptions.
JKD-514COM provides:
Audible Alarm
and
Visual Indication
within the same product.
This dual warning method gives occupants more than one form of alarm indication.
The product is designed as a combined smoke and carbon monoxide alarm, so the same compact housing integrates sensing electronics, alarm sound output, visual indicators and two dedicated sensor technologies.
For retailers, the message is easy to communicate:
Smoke and CO monitoring with sound and light warning in one residential alarm.
Smoke monitoring is performed by a:
Photoelectric Reflection Sensor
with a specified smoke alarm sensitivity of:
0.25dB/m
The smoke alarm function follows:
EN14604:2005/AC:2008
JKD-514COM also includes an approximately:
10-minute smoke alarm silence function.
This combination allows the model to be positioned as a photoelectric smoke alarm with audible and visual warning, while simultaneously providing carbon monoxide monitoring.
Carbon monoxide requires a different sensing technology.
JKD-514COM therefore incorporates a dedicated:
Electrochemical CO Sensor
The carbon monoxide alarm function conforms to:
EN50291-1:2018
with specified response characteristics:
| CO Concentration | Alarm Response |
|---|---|
| 50ppm | Within 60 to 90 Minutes |
| 100ppm | Within 10 to 40 Minutes |
| 300ppm | Within 3 Minutes |
These defined response levels provide professional buyers with measurable technical information when evaluating a home carbon monoxide alarm or electrochemical CO sensor.
Installing separate products for different hazards is common, but combined products can provide another option for suitable residential applications.
JKD-514COM integrates:
Smoke Sensor
plus
CO Sensor
plus
Audible Warning
plus
Visual Warning
inside one compact housing.
This makes it a useful combination smoke and CO alarm for home use, particularly for retailers and distributors that want to offer both standalone and combined safety products.
JKD-514COM has a specified:
10 Year Product Life After Manufacture
This gives the model a long-term residential product position rather than an entry-level short-life profile.
The alarm uses replaceable AA alkaline batteries, providing a familiar power architecture for household users.
The average standby current is:
Less than 50μA
and the average alarm current is:
Less than 70mA.
These electrical specifications support continuous battery-powered monitoring during everyday operation.
The two sensing functions are supported by two corresponding European product standards.
For smoke:
EN14604:2005/AC:2008
For carbon monoxide:
EN50291-1:2018
JKD-514COM is also supported by:
SGS Certification
RoHS
EMC
UKCA
This documentation package is relevant for importers, wholesalers, retailers and private-label brands evaluating a certified smoke and carbon monoxide alarm for the European market.
The specified detection range is:
Maximum 40m² Within a Room
JKD-514COM supports:
Ceiling Installation
or:
Wall Installation
according to the supplied instructions and applicable requirements.
Operating conditions are specified between:
-10°C and +50°C
with:
Less than 95 percent RH non-condensing.
These characteristics make the alarm suitable for appropriate residential applications in houses, apartments, rental properties and other home environments.
The approximate dimensions are:
Φ105 x 39mm
with a net weight of approximately:
180 plus or minus 10g.
Within this compact housing, JKD-514COM combines:
- Photoelectric smoke sensing
- Electrochemical CO sensing
- Audible warning
- Visual indication
- Battery-powered electronics
For distributors, this creates a practical combined safety SKU without requiring separate housings for the two sensing functions provided by the product.
Many product descriptions focus heavily on sensor type and certification.
However, warning output should also be part of the purchasing evaluation.
JKD-514COM provides a measurable specification:
At Least 85dB at 3 Meters
combined with visual indication.
For B2B buyers, this means the product can be compared using concrete technical data rather than unsupported claims such as "extra loud" or "powerful."
The complete selling proposition becomes:
Photoelectric smoke sensing
Electrochemical CO sensing
Visual alarm indication
At least 85dB audible warning
10-year product life
EN14604 and EN50291
This gives distributors several concrete features to communicate to customers.
JKD-514COM supports OEM, ODM and private-label cooperation for:
- Home safety brands
- Fire safety distributors
- Electrical wholesalers
- DIY retailers
- Residential safety suppliers
- Importers
Customization can include customer logos, product labels, retail packaging, multilingual manuals, barcodes and master cartons.
| Technical Item | Specification |
|---|---|
| Model | JKD-514COM |
| Product Type | Smoke and Carbon Monoxide Alarm |
| Product Life | 10 Years After Manufacture |
| Power Supply | AA Alkaline Batteries |
| Type of Apparatus | Type B Visual and Audible Alarm Only |
| Alarm Method | Visual and Audible Warning |
| Alarm Sound Pressure | At Least 85dB at 3m |
| Smoke Sensor | Photoelectric Reflection |
| Smoke Alarm Sensitivity | 0.25dB/m |
| Smoke Silence Function | About 10 Minutes |
| Smoke Standard | EN14604:2005/AC:2008 |
| CO Sensor | Electrochemical |
| CO Standard | EN50291-1:2018 |
| CO Response at 50ppm | 60 to 90 Minutes |
| CO Response at 100ppm | 10 to 40 Minutes |
| CO Response at 300ppm | Within 3 Minutes |
| Standby Current | Less Than 50μA Average |
| Alarm Current | Less Than 70mA Average |
| Operating Temperature | -10°C to +50°C |
| Operating Humidity | Less Than 95 Percent RH Non Condensing |
| Storage and Transport Temperature | -10°C to +50°C |
| Storage and Transport Humidity | Less Than 95 Percent RH Non Condensing |
| Installation Location | Ceiling or Wall |
| Detection Range | Maximum 40m² Within a Room |
| Dimensions | Approx. Φ105 x 39mm |
| Weight | Approx. 180 Plus or Minus 10g |
| Certification | SGS |
| Additional Compliance | RoHS EMC UKCA |
| OEM | Supported |
| ODM | Supported |
| Private Label | Supported |
JKD-514COM is supported by:
SGS Certification
EN14604:2005/AC:2008 Smoke Alarm Standard
EN50291-1:2018 Carbon Monoxide Alarm Standard
RoHS
EMC
UKCA
Technical datasheets, specifications, user manuals and applicable certification documents can be provided for B2B product evaluation.
How loud is the JKD-514COM alarm?
The specified audible alarm sound pressure is at least 85dB at 3 meters.
Does it provide a visual warning?
Yes. JKD-514COM provides both visual and audible alarm indication.
Does it monitor smoke and carbon monoxide?
Yes. It combines a photoelectric smoke sensor and an electrochemical CO sensor.
What is the smoke sensitivity?
The specified smoke alarm sensitivity is 0.25dB/m.
Which standards does the alarm follow?
The smoke function follows EN14604:2005/AC:2008, while the CO function follows EN50291-1:2018.
What is the product life?
The specified product life is 10 years after manufacture.
Is JKD-514COM SGS certified?
Yes.
What is the specified room coverage?
The specified detection range is maximum 40m² within a room.
Can it be supplied under our own brand?
Yes. OEM, ODM and private-label manufacturing are supported.