10 Year Smoke and Carbon Monoxide Alarm with Replaceable AA Battery Power
| Place of Origin | China |
|---|---|
| Brand Name | Symank |
| Certification | SGS/CE/ROHS/UKCA |
| Model Number | JKD-514COM |
| Minimum Order Quantity | 100pcs |
| Price | Negotiable |
| Packaging Details | Color box,size:110×55×110mm,60pcs in one carton,carton size:61x30x28cm |
| Delivery Time | 5 days |
| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 50K/Month |
| Product Name | Smoke Carbon Monoxide Detectors | Silencebutton | Yes, To Temporarily Silence Alarm |
|---|---|---|---|
| Installationlocation | Wall Or Ceiling Mount | Testbutton | Yes, For Manual Testing |
| Displaytype | Digital LCD / LED Indicator | Endoflifewarning | Light Alert When Detector Needs Replacement |
| Alarmsoundlevel | 85 DB At 10 Feet | Detectiontype | Smoke And Carbon Monoxide |
| Operatingtemperaturerange | -10°C To 50°C (14°F To 122°F) | Dimensions | 105mm Diameter |
| Certifications | EN14604,EN50291 | Powersource | Battery-operated |
| Sensortype | Electrochemical (for CO), Photoelectric Or Ionization (for Smoke) | ||
| Highlight | High Sensitivity Smoke Carbon Monoxide Detectors,EN14604 Certified Smoke And CO Alarm,EN50291 Certified Smoke And CO Alarm |
||
Long-life residential alarms are increasingly associated with sealed lithium batteries, but sealed power is not the only option for a 10-year product.
Some homeowners, retailers and distributors still prefer a familiar power architecture where batteries can be replaced when required.
The JKD-514COM smoke and carbon monoxide alarm combines a 10-year product life with replaceable AA alkaline battery power, providing an alternative for markets where accessible and familiar battery maintenance remains important.
At the same time, the unit combines a photoelectric smoke sensor and an electrochemical CO sensor, allowing one alarm to monitor two different residential hazards.
For B2B buyers, the purchasing reason is clear:
A 10-year combination smoke and CO alarm built around familiar replaceable battery power.
Sealed lithium batteries provide important advantages, but different markets have different preferences.
AA alkaline batteries are among the most familiar battery formats worldwide. Consumers know how to purchase, install and replace them, while retailers already have an established supply chain for replacement batteries.
This can make an AA battery smoke and CO alarm particularly attractive for traditional retail channels.
The user is not dependent on a proprietary battery pack, and the power source can be managed according to the product instructions during the alarm's service life.
For distributors, this creates a different sales proposition from sealed-battery products rather than simply a lower-cost alternative.
JKD-514COM has a specified:
This gives distributors the ability to offer a 10 year smoke and carbon monoxide alarm while retaining a replaceable battery format.
The combination can be especially useful for buyers who want long-life residential safety products but whose customers remain accustomed to standard battery-powered alarms.
It also provides a useful additional SKU alongside sealed lithium products, allowing a brand to address different consumer preferences within the same smoke and CO category.
JKD-514COM combines two sensing technologies inside one housing.
The smoke alarm function uses photoelectric reflection technology.
The carbon monoxide function uses an independent electrochemical sensing element.
Smoke and carbon monoxide are different hazards and require different sensing principles.
By combining both technologies, JKD-514COM provides a dual sensor smoke and CO alarm without requiring homeowners to purchase two separate products for the functions provided by the unit.
The smoke sensing function has a specified sensitivity of:
0.25dB/m
and includes an approximately:
10-minute smoke alarm silence function.
The smoke function follows:
This allows the product to address buyers searching for an EN14604 photoelectric smoke alarm, while also providing integrated carbon monoxide monitoring.
Carbon monoxide is invisible and cannot be identified by smell.
JKD-514COM therefore incorporates a dedicated:
The carbon monoxide function conforms to:
EN50291-1:2018
with the following specified alarm response:
| CO Concentration | Alarm Response |
|---|---|
| 50ppm | 60 to 90 Minutes |
| 100ppm | 10 to 40 Minutes |
| 300ppm | Within 3 Minutes |
These measurable response values are particularly important for professional buyers comparing different residential carbon monoxide alarms.
JKD-514COM is supported by:
SGS Certification
EN14604:2005/AC:2008
EN50291-1:2018
RoHS
EMC
UKCA
This certification structure makes the model suitable for importers, wholesalers and private-label brands evaluating products for European and UK residential safety markets.
For B2B buyers, certifications and technical documentation can be just as important as appearance or price when selecting a long-term supplier.
A battery-powered home safety alarm spends most of its service time continuously monitoring the environment.
JKD-514COM has a specified average standby current of:
Average alarm current is:
These measurable electrical specifications provide professional buyers with useful information when evaluating a battery operated smoke and carbon monoxide alarm.
JKD-514COM is a:
Type B apparatus designed to provide visual and audible alarm only.
The specified alarm sound pressure reaches:
This provides occupants with a clear audible warning when an applicable smoke or carbon monoxide alarm condition occurs.
JKD-514COM supports:
Ceiling Installation
and
Wall Installation
according to the product instructions.
The specified detection range is:
Its compact dimensions of approximately Φ105 x 39mm allow the combined alarm to fit into a wide range of residential interiors.
Potential applications include houses, apartments, bedrooms, living areas, rental properties and other residential environments.
JKD-514COM can help distributors address customers who specifically prefer replaceable battery products.
Its positioning combines:
- 10 Year Product Life
- Replaceable AA Battery Power
- Smoke and CO Monitoring
- Photoelectric Smoke Sensor
- Electrochemical CO Sensor
- SGS Certification
- EN14604
- EN50291
- RoHS
- EMC
- UKCA
Rather than relying on generic claims such as premium or advanced, every purchasing point represents a concrete product characteristic.
For OEM and private-label customers, customized logos, packaging, labels, multilingual manuals, barcodes and master cartons can also be supported.
| Technical Item | Specification |
|---|---|
| Model | JKD-514COM |
| Product Type | Smoke and Carbon Monoxide Alarm |
| Product Life | 10 Years After Manufacture |
| Power Supply | AA Alkaline Batteries |
| Type of Apparatus | Type B Visual and Audible Alarm Only |
| Smoke Sensor | Photoelectric Reflection |
| Smoke Alarm Sensitivity | 0.25dB/m |
| Smoke Alarm Silence | About 10 Minutes |
| Smoke Standard | EN14604:2005/AC:2008 |
| CO Sensor | Electrochemical |
| CO Standard | EN50291-1:2018 |
| 50ppm CO Response | 60 to 90 Minutes |
| 100ppm CO Response | 10 to 40 Minutes |
| 300ppm CO Response | Within 3 Minutes |
| Standby Current | Less Than 50μA Average |
| Alarm Current | Less Than 70mA Average |
| Alarm Method | Visual and Audible Alarm |
| Alarm Sound Pressure | At Least 85dB at 3m |
| Operating Temperature | -10°C to +50°C |
| Operating Humidity | Less Than 95 Percent RH Non Condensing |
| Storage Temperature | -10°C to +50°C |
| Storage Humidity | Less Than 95 Percent RH Non Condensing |
| Installation Location | Ceiling or Wall |
| Detection Range | Maximum 40m² Within a Room |
| Dimensions | Approx. Φ105 x 39mm |
| Certification | SGS |
| Additional Compliance | RoHS EMC UKCA |
| OEM | Supported |
| ODM | Supported |
| Private Label | Supported |
JKD-514COM is supported by:
SGS Certification
EN14604:2005/AC:2008 Smoke Alarm Standard
EN50291-1:2018 Carbon Monoxide Alarm Standard
RoHS
EMC
UKCA
Technical specifications, user manuals, datasheets and applicable certification documentation can be provided for B2B product evaluation.
The specified product life is 10 years after manufacture.
Yes. JKD-514COM uses replaceable AA alkaline battery power.
Yes. It combines a photoelectric smoke sensor with an electrochemical CO sensor.
The smoke function follows EN14604:2005/AC:2008.
The CO function follows EN50291-1:2018.
Yes.
The specified alarm sound pressure is at least 85dB at 3 meters.
Yes. Both ceiling and wall installation are supported according to the product instructions.
Yes. OEM, ODM and private-label projects are supported.